18
Connect heating water flow and heating water return at the heat
pump
!
Please note
Avoid appliance damage:
■ Fit supplied connecting hoses
(bends) so that they are free of
load and torque stress.
■ To prevent transmission of any
vibration, the connecting hoses
must not contact any other
components.
Note
■ The connecting hoses can be short-
ened.
■ Completely encase connecting hoses
in the supplied thermal insulation.
C
A
B
1.
4.
3.
2x
2x
2.
A
Heating water return
B
Heating water flow
C
Hydraulic connection set (acces-
sory)
Installation sequence
Making the hydraulic connections
5516 436 GB