Type AWO-M/AWO-M-E/AWO-M-E-AC
201.A04
201.A06
201.A08
201.A10
201.A13
201.A16
Indoor unit electrical values
Heat pump control unit/PCB
– Rated voltage, control unit/PCB
1/N/PE 230 V/50 Hz
– Power supply fuse rating
1 x B16A
1 x B16 A
1 x B16 A
1 x B16 A
1 x B16 A
1 x B16 A
– Internal fuse
6.3 A (slow)/250 V
Instantaneous heating water heater
– Type AWO-M-E/AWO-M-E-AC: Facto-
ry-fitted
– Type AWO-M: Accessories
– Rated voltage
1/N/PE 230 V/50 Hz
or
3/N/PE 400 V/50 Hz
– Heating output
kW
9
9
9
9
9
9
– Power supply fuse rating
3 x B16A
3 x B16 A
3 x B16 A
3 x B16 A
3 x B16 A
3 x B16 A
Max. power consumption
Fan
W
45
45
115
2 x 115
2 x 115
2 x 115
Outdoor unit
kW
2.85
3.20
3.30
4.55
5.08
5.08
Secondary pump (PWM)
W
60
60
60
60
60
60
– Energy efficiency index EEI
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
≤ 0.2
Control unit/PCB, outdoor unit
W
15
15
15
15
15
15
Control unit/PCB, indoor unit
W
10
10
10
10
10
10
Control unit/PCB power, indoor unit
W
1000
1000
1000
1000
1000
1000
Refrigerant circuit
Refrigerant
R410A
R410A
R410A
R410A
R410A
R410A
– Refrigerant charge
kg
1.40
1.40
1.40
2.40
2.40
2.40
– Global warming potential (GWP)
*1
1924
1924
1924
1924
1924
1924
– CO
2
equivalent
t
2.7
2.7
2.7
4.6
4.6
4.6
Compressor (hermetically sealed)
Type
Scroll
Scroll
Scroll
Scroll
Scroll
Scroll
– Oil in compressor
Type
3 MAF POE 3 MAF POE 3 MAF POE 3 MAF POE 3 MAF POE
3 MAF POE
– Quantity of oil in compressor
l
0.76
0.76
0.76
1.17
1.17
1.17
Permissible operating pressure
– High pressure side
bar
43
43
43
43
43
43
MPa
4.3
4.3
4.3
4.3
4.3
4.3
– Low pressure side
bar
28
28
28
28
28
28
MPa
2.8
2.8
2.8
2.8
2.8
2.8
Outdoor unit dimensions
Total length
mm
546
546
546
546
546
546
Total width
mm
1109
1109
1109
1109
1109
1109
Total height
mm
753
753
753
1377
1377
1377
Indoor unit dimensions
Total length
mm
370
370
370
370
370
370
Total width
mm
450
450
450
450
450
450
Total height
mm
880
880
880
880
880
880
Total weight
Outdoor unit
kg
102
102
103
145
145
145
Indoor unit
– Type AWO-M
kg
40
40
40
40
40
40
– Type AWO-M-E/AWO-M-E-AC
kg
41
41
41
41
41
41
Permissible operating pressure
, sec-
ondary side
bar
3
3
3
3
3
3
MPa
0.3
0.3
0.3
0.3
0.3
0.3
Connections
(female thread)
Heating water flow
G
1¼
1¼
1¼
1¼
1¼
1¼
Heating water return and DHW cylinder
return
G
1¼
1¼
1¼
1¼
1¼
1¼
DHW cylinder flow
G
1¼
1¼
1¼
1¼
1¼
1¼
Secondary circuit flow
G
1¼
1¼
1¼
1¼
1¼
1¼
Secondary circuit return
G
1¼
1¼
1¼
1¼
1¼
1¼
Length of connection line between in-
door and outdoor units
(Hydraulic con-
nection set)
m
1 to 20
1 to 20
1 to 20
1 to 20
1 to 20
1 to 20
Sound power of outdoor unit
at rated heating output
(Measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
– At A7
±3 K
/W55
±5 K
(max.)
dB(A)
56
56
58
60
61
61
– At A7
±3 K
/W55
±5 K
in night mode
dB(A)
50
50
50
55
55
55
*1
Based on the Fifth Assessment Report of the Intergovernmental Panel on Climate Change (IPCC)
Vitocal 200-A
(cont.)
10
VIESMANN
VITOCAL
2
5831388