6.2 Ventilation unit
Vitovent ventilation units
Vitovent mechanical ventilation systems with central ventilation unit
can be fully controlled via the heat pump control unit. The heat pump
control unit has the entire range of functions required for operation,
control parameter configuration and diagnostics of the connected
ventilation unit.
Note
For detailed information on designing a mechanical ventilation sys-
tem with a central ventilation unit: See technical guide "Central
mechanical ventilation systems with heat recovery".
Vitovent
Type
Part no.
Countercurrent
heat exchanger
Enthalpy heat ex-
changer
Max. air flow rate in
m
3
/h
Max. residential unit
area in m
2
200-C
H11S A200
Z014599
(L)
Z015391
(R)
X
200
120
H11E A200
Z014584
(L)
Z015392
(R)
X
200
120
300-W
H32S B300
Z014589
X
300
230
H32E B300
Z014582
X
300
230
H32S B400
Z014590
X
400
370
H32E B400
Z014583
X
400
370
300-C
H32S B150
Z014591
X
150
90
300-F
H32S B280
Z011432
(w)
Z012121
(s)
X
280
180
H32E C280
Z014585
(w)
Z014586
(s)
X
280
180
(L) Supply air connection, left
(R) Supply air connection, right
(w) Colour: White
(s) Colour: Vitosilver
6.3 Heating water buffer cylinder
Vitocell 100-W, type SVPA, white
Part no. Z015310
Colour: White
Wall mounted heating water buffer cylinder for installation in the sec-
ondary circuit return
■ For storing heating water in conjunction with heat pumps with up to
17 kW heating output
■ For ensuring the minimum system volume
Standard delivery:
■ Heating water buffer cylinder with EPS thermal insulation and
sheet steel casing
■ Wall mounting bracket
■ Overflow valve DN 25, R 1
Specification
Cylinder capacity
(AT: Actual water capacity)
l
46
Max. flow temperature
°C
95
Max. operating pressure
bar
3
MPa
0.3
Weight
kg
18
Connections
(male thread)
Heating water flow and return
G
1¼
Standby heat loss
kWh/24 h
0.94
Energy efficiency class
B
Installation accessories
(cont.)
58
VIESMANN
VITOCAL
6
5831388