Type AWO/AWO-E/AWO-E-AC
201.A10
201.A13
201.A16
Connections
(female thread)
Heating water flow
G
1¼
1¼
1¼
Heating water return and DHW cylinder return
G
1¼
1¼
1¼
DHW cylinder flow
G
1¼
1¼
1¼
Secondary circuit flow
G
1¼
1¼
1¼
Secondary circuit return
G
1¼
1¼
1¼
Length of connection line between indoor and out-
door units
(Hydraulic connection set)
m
1 to 20
1 to 20
1 to 20
Sound power of outdoor unit
at rated heating output
(Measurements with reference to EN 12102/EN ISO 9614-2)
Weighted total sound power level
– At A7
±3 K
/W55
±5 K
(max.)
dB(A)
61
61
61
– At A7
±3 K
/W55
±5 K
in night mode
dB(A)
55
55
55
Energy efficiency class
to EU Regulation no. 813/2013
Heating, average climatic conditions
– Low temperature applications (W35)
A
+++
*4
A
+++
*4
A
+++
*4
– Medium temperature applications (W55)
A
++
A
++
A
++
Performance data
as per EU Regulation no. 813/2013
(average climatic conditions)
Low temperature applications (W35)
– Energy efficiency η
S
%
180
182
182
– Rated heating output P
rated
kW
9.75
10.99
11.65
– Seasonal coefficient of performance (SCOP)
4.58
4.64
4.62
Medium temperature applications (W55)
– Energy efficiency η
S
%
132
134
134
– Rated heating output P
rated
kW
9.67
11.00
11.98
– Seasonal coefficient of performance (SCOP)
3.37
3.42
3.42
Sound power level to ErP
Sound power level, outdoor unit
dB(A)
56
56
56
Note
Reduced noise night mode can be enabled at the heat pump control
unit at the "Contractor" setting level.
*4
The new energy efficiency class A
+++
comes into effect on 26 September 2019.