![Viessmann VD2-1080 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/viessmann/vd2-1080/vd2-1080_installation-instructions-manual_1016938027.webp)
27
5285 429 - 03
Vitorond 200, VD2 Series 320 to 1080 Installation
Enclosure
Enclosure Installation
1. Install cross bar supports according to measurements
listed in table below to casting notches, using the
16 x 80 bolts, washers and flat nuts.
Crossbar supports
Boiler model VD2-
320
380
440
500
560
630
700
780
860
950
1080
a
in.
(mm)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
31
c
(805)
36
c
(932)
26
c
(679)
b
in.
(mm)
-
-
-
19
c
(502)
19
c
(502)
19
c
(502)
24
c
(628)
24
c
(628)
29
c
(755)
29
c
(755)
19
c
(502)
c
in.
(mm)
-
-
-
-
-
-
-
-
-
-
24
c
(628)
All components required for mounting the insulation are
included with the insulation material.
Boiler