2.1 Compensation for uneven floor
(Please note accompanying coldroom drawing)
Mark shape of coldroom on floor with chalk.
2.2 Coldrooms with flooring ventilation
(Coldroom temperature under - 5°C)
The flooring gratings are laid loosely at a distance of 200 to
300 mm from each other. Ensure that the joins (B) and the
exterior edges (A) are placed exactly on the flooring
gratings. lf there is unevenness in the flooring, the flooring
gratings must be adjusted for height. The adjustment for
height may be done using damp cement, fast setting
adhesives or compensation plating. The adjustment should
begin at the highest point.
2.3 Coldrooms without flooring ventilation
In case of uneven or non horizontal flooring, compensate
using floor underlays.