Safety, Installation and Warranty Requirements
2
Safety, Installation and Warranty Requirements
Please ensure that this manual is read and understood before commencing installation. Failure to comply
with the issues listed below
and details printed in this manual can cause
product/property damage
,
severe personal injury
, and/or
loss of life
. Ensure all
requirements below are understood and fulfilled (including detailed information found in manual subsections).
Each of the following issues is very important and is discussed in detail in the boiler technical literature. Ensure that the installation
complies fully and completely with all requirements set out in the boiler technical literature.
H
Licensed professional heating
contractor
The installation, adjustment, service,
and maintenance of this equipment
must be
performed by a licensed
professional heating contractor.
"
Please see section
entitled “Important
Regulatory and
Installation
Requirements”.
H
Product documentation
Read all applicable documentation
before commencing installation. Store
documentation near boiler in a readily
accessible location for reference in
the future by service personnel.
"
For a listing of
applicable literature,
please see section
entitled “Important
Regulatory and
Installation Requirements”.
H
Advice to owner
Once the installation work is
complete, the heating contractor must
familiarize the system
operator/ultimate owner with all
equipment, as well as safety
precautions/requirements, shut-down
procedure, and the need for
professional service annually before
the heating season begins.
H
Contaminated air
Air contaminated by chemicals can
cause by-products in the combustion
process which are
poisonous
to
inhabitants and destructive to
Viessmann equipment.
H
Carbon monoxide
Improper installation, adjustment,
service and/or maintenance can cause
flue products to flow into living space.
Flue products contain
poisonous
carbon monoxide gas.
H
Fresh air
This equipment requires fresh air for
safe operation and must be installed
ensuring provisions for
adequate
combustion
and
ventilation air
exist.
H
Equipment venting
Never operate boiler without an
installed venting system
.
H
Warranty
Information contained in
this and related product
documentation must be
read and followed.
Failure
to do so renders warranty
null and void.
5
2
6
5
6
6
5
v
2
.5
Do not store chemicals containing
chlorine or other corrosive materials
near the boiler, such as bleach,
cleaning solvents, detergents, acids,
hair spray, spray cans, paint thinners,
paint, water softener salt,
refrigerants, etc.
WARNING
Installers must follow local
regulations with respect to
installation of carbon monoxide
detectors. Follow manufacturer’s
maintenance schedule of boiler.
WARNING
Never operate the burner without an
adequate supply of fresh combustion
air. All the combustion and ventilation
air must be supplied from the outside.
Failure to heed this warning can
cause severe personal injury or loss
of life.
WARNING
Improper, incomplete, obstructed, or
deteriorated vent system can present
a serious risk of flue gases leaking
into living space which could cause
carbon monoxide poisoning.