Safety, Installation and Warranty Requirements

2

Safety, Installation and Warranty Requirements

Please ensure that this manual is read and understood before commencing installation. Failure to comply

with the issues listed below

and details printed in this manual can cause

product/property damage

,

severe personal injury

, and/or

loss of life

. Ensure all

requirements below are understood and fulfilled (including detailed information found in manual subsections).

Each of the following issues is very important and is discussed in detail in the boiler technical literature. Ensure that the installation

complies fully and completely with all requirements set out in the boiler technical literature.

H

Licensed professional heating
contractor

The installation, adjustment, service,
and maintenance of this equipment

must be

performed by a licensed

professional heating contractor.

"

Please see section

entitled “Important
Regulatory and
Installation
Requirements”.

H

Product documentation

Read all applicable documentation

before commencing installation. Store
documentation near boiler in a readily
accessible location for reference in
the future by service personnel.

"

For a listing of

applicable literature,
please see section
entitled “Important
Regulatory and
Installation Requirements”.

H

Advice to owner

Once the installation work is
complete, the heating contractor must
familiarize the system
operator/ultimate owner with all
equipment, as well as safety
precautions/requirements, shut-down
procedure, and the need for
professional service annually before
the heating season begins.

H

Contaminated air

Air contaminated by chemicals can
cause by-products in the combustion
process which are

poisonous

to

inhabitants and destructive to
Viessmann equipment.

H

Carbon monoxide

Improper installation, adjustment,
service and/or maintenance can cause
flue products to flow into living space.
Flue products contain

poisonous

carbon monoxide gas.

H

Fresh air

This equipment requires fresh air for
safe operation and must be installed
ensuring provisions for

adequate

combustion

and

ventilation air

exist.

H

Equipment venting

Never operate boiler without an

installed venting system

.

H

Warranty

Information contained in
this and related product
documentation must be
read and followed.

Failure

to do so renders warranty
null and void.

5

2

6

5

6

6

5

v

2

.5

Do not store chemicals containing
chlorine or other corrosive materials
near the boiler, such as bleach,
cleaning solvents, detergents, acids,
hair spray, spray cans, paint thinners,
paint, water softener salt,
refrigerants, etc.

WARNING

Installers must follow local
regulations with respect to
installation of carbon monoxide
detectors. Follow manufacturer’s
maintenance schedule of boiler.

WARNING

Never operate the burner without an
adequate supply of fresh combustion
air. All the combustion and ventilation
air must be supplied from the outside.
Failure to heed this warning can
cause severe personal injury or loss
of life.

WARNING

Improper, incomplete, obstructed, or
deteriorated vent system can present
a serious risk of flue gases leaking
into living space which could cause
carbon monoxide poisoning.

WARNING

Содержание Riello

Страница 1: ...oisoning resulting in injury or loss of life This product must be installed and serviced by a professional service technician who is experienced and qualified in hot water boiler installation and gas...

Страница 2: ...ements shut down procedure and the need for professional service annually before the heating season begins H Contaminated air Air contaminated by chemicals can cause by products in the combustion proc...

Страница 3: ...Product Delivery 4 Mounting Burner 5 Burner Set up Gas 6 Burner Set up Oil 10 Oil Cartridge Assembly 13 Burner Set up Gas and Oil 13 Start up Appendix Start up Information 14 Technical Data 15 Wiring...

Страница 4: ...tomatically Fired Boilers ANSI ASME CSD 1 where required by the authority having jurisdiction Working on the equipment The installation adjustment service and maintenance of this boiler must be done b...

Страница 5: ...Remove burner from carton The universal mounting flange has been installed on the burner at the factory 2 Mount burner as shown in Figs 1 and 2 5265 665 v2 5 Fig 1 Installing burner Fig 2 Securing bu...

Страница 6: ...l gas solenoid valve V8295 N C 24 V operated Dungs MVD LE model 200 G200 MVD LE 205 6 24 V G400 MVD LE 207 6 24 V Gas burner manifold test point Gas piping pressure test The burner and its gas connect...

Страница 7: ...ance regulator and set to required burner manifold pressure setting Use factory default settings pages 15 and 16 as starting point only 4 To adjust the initial lift gas pressure remove sealing cap exp...

Страница 8: ...r for both natural and propane gas Do not use other gas valve unless specified by Viessmann Field measured combustion results Use the combustion data label packed with the gas burner to record field m...

Страница 9: ...y supplied with a 40 N P 200 aftermarket conversion burner to that stated in the table below The differences in orifice size for the VB2 18 22 cause the manifold pressure adjustment information in the...

Страница 10: ...vided with its own oil filter and built in flow check valve The flow check valve is located in the return and a manual shut off is located in the supply One pipe systems 1 Connect as shown in Fig 6 52...

Страница 11: ...ront of the boiler Fig 8 3 Mount filter and check valve assembly to mounting bracket Fig 9 Filter is disposable type and must be replaced with the filter cartridge supplied by Viessmann 5265 665 v2 5...

Страница 12: ...s plug already installed ready for two pipe connection For a one pipe system gravity system where the oil tank is above the burner use the copper tee provided This tee converts the two pipe system to...

Страница 13: ...on Ensure an adequate supply of fresh combustion and ventilation air for safe operation Refer to codes mentioned on page 4 Electrical connections 1 Run the plug in connector cable of the Vitotronic co...

Страница 14: ...ler and barometric draft regulator before dilution air see the installation manual Overfire draft is measured at the combustion chamber observation port opening The expected CO2 products of combustion...

Страница 15: ...use unsafe conditions Viessmann strongly recommends the installation of an approved type CO detector in the vicinity of any gas burning equipment Observe national and or local code requirements If in...

Страница 16: ...lues can cause unsafe conditions Viessmann strongly recommends the installation of an approved type CO detector in the vicinity of any gas burning equipment Observe national and or local code requirem...

Страница 17: ...e Flow USGPH MBH 0 59 83 0 76 107 0 96 135 1 21 170 1 56 219 2 14 300 Pump Pressure psig kPa 150 1034 170 1172 145 1000 170 1122 165 1138 175 1207 Air Tube Length inches mm 10 254 10 254 10 254 10 254...

Страница 18: ...r 120 VAC is supplied to burner via plug in connector Do not connect additional 120 VAC to burner If any of the original wires as supplied with the appliance must be replaced replace with 221 F 105 C...

Страница 19: ...ate wiring harness strain relief to other electrical opening provided 3 Disconnect black wire BK of 7 pole plug from oil burner primary control base 4 Rewire wire nut included the black wire BK throug...

Страница 20: ...ch heating season begins have the following service and maintenance done by a licensed professional heating contractor 1 Boiler heat exchanger inspected and cleaned 2 Vent system inspected for deterio...

Страница 21: ...Appendix 21 Notes 5265 665 v2 5...

Страница 22: ...Appendix 22 Notes 5265 665 v2 5...

Страница 23: ...n D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas contro...

Страница 24: ...2 oil H BHP x 9 8 kW H BHP x 33779 Btu H m x 3 28 ft H m3 x 35 3 ft 3 H kcal x 3968 Btu H Cal value NG 950 1050 Btu ft 3 H Cal value LP 2450 2500 Btu ft 3 H Motor kW x 1 31 Motor HP NG Natural Gas LP...

Отзывы: