16
Coding in the delivered condition
Possible change
Fan speed, burner
0D:80
Flue gas fan speed when
the burner is in operation
as a percentage of the
maximum speed.
0D:0
to
0D: 100
Setting range from 0 to 100
percent.
Heating
Coding
Coding in the delivered condition
Possible change
Summer eco function room temperature
A5:5
With heating circuit pump
logic function (economy
mode): Heating circuit
pump „OFF“, if outside
temperature (AT) 1 K is
greater than the room
temperature set value
(RTset ) AT > RTset + 1
K
A5:0
Without heating circuit
pump logic
A5:1
to
A5:15
With heating circuit pump
logic function: Heating cir-
cuit pump „OFF“ see fol-
lowing table
1
AT > RT
set
+ 5 K
2
AT > RT
set
+ 4 K
3
AT > RT
set
+ 3 K
4
AT > RT
set
+ 2 K
5
AT > RT
set
+ 1 K
6
AT > RT
set
7
to
AT > RT
set
−
1 K
to
15
AT > RT
set
−
9 K
Codes
Code 1
(cont.)
5604 447 GB
Содержание KOB Pyromat ECO
Страница 42: ...42 230V connection Designs Connection and wiring diagram 5604 447 GB ...
Страница 43: ...43 LV connection Designs Connection and wiring diagram cont 5604 447 GB ...
Страница 46: ...46 Plug X1 Drawing assignment 1 6 1 2 3 4 5 6 7 X1 Designs 230 V plug cont 5604 447 GB ...
Страница 57: ...57 030 022 021 020 025 031 031 012 019 025 044 024 024 035 Parts lists Parts lists cont 5604 447 GB ...
Страница 58: ...58 008 004 001 002 032 043 037 038 007 007 007 009 002 005 Parts lists Parts lists cont 5604 447 GB ...
Страница 59: ...59 006 006 006 007 034 036 013 015 018 014 016 033 017 015 003 Parts lists Parts lists cont 5604 447 GB ...