62
Power-OFF with on-site load disconnection
The power-OFF signal is connected to
the on-site contactor of the economy tar-
iff power supply and to the heat pump
control unit. When power-OFF is ena-
bled, the compressor
and
the instanta-
neous heating water heater (if installed)
are "forced" off, and in the 2-stage ver-
sion (type BW + BWS),
both
compres-
sors
and
the instantaneous heating
water heater are switched off.
Note
Observe the technical connection condi-
tions of the relevant power supply util-
ity.
Single stage
C
B
A
≈
F
H
5
4
3
4
4
3
3/N
3/N
G
K
4
kWh
kWh
3
E
D
X3.7
X3.6
Diagram excluding fuses and RCD.
Installation sequence
Power supply
(cont.)
5546 273 GB