130
Heating circuit 3
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Standard room temperature"
4000
200 (
≙
20 °C)
"Reduced room temperature"
4001
200 (
≙
20 °C)
"Remote control"
4003
0
"Heating curve level"
4006
0 (
≙
0 K)
"Heating curve slope"
4007
6 (
≙
0.6)
"Influence room temperature
hook-up"
400 A 10
"Room temperature hook-up"
400 B 0
"Max. flow temperature heat-
ing circuit"
400E
400 (
≙
40 °C)
"Room temperature in party
mode"
4022
160 (
≙
16 °C)
Cooling
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Cooling function"
7100
0
"Cooling circuit"
7101
1
"Set room temperature sepa-
rate cooling circuit"
7102
200 (
≙
20 °C)
"Min. flow temperature cool-
ing"
7103
100 (
≙
10 °C)
"Influence room temperature
hook-up cooling circuit"
7104
0
"Ranking room temp sensor
separate cooling circuit"
7106
0
"Cooling curve level"
7110
0 (
≙
0 K)
"Cooling curve slope"
7111
12 (
≙
1.2)
"Remote control cooling circ"
7116
0
"Enable coolant buffer cylin-
der"
7120
0
"Enable active cooling"
71FE
0
Commissioning/service reports
Control parameters report
(cont.)
5546 273 GB