144
Type AWB/AWB-E-AC
201.D10
201.D13
201.D16
Secondary circuit connections
(female
thread)
Heating water flow
G
1
¼
1
¼
1
¼
Heating water return and DHW cylinder return
G
1
¼
1
¼
1
¼
DHW cylinder flow
G
1
¼
1
¼
1
¼
Refrigerant line connections
Liquid line
■
Pipe
7
mm
10 x 1
10 x 1
10 x 1
■
Indoor unit
UNF
⅝
⅝
⅝
■
Outdoor unit
UNF
⅝
⅝
⅝
Hot gas line
■
Pipe
7
mm
16 x 1
16 x 1
16 x 1
■
Indoor unit
UNF
⅞
⅞
⅞
■
Outdoor unit
UNF
⅞
⅞
⅞
Length of liquid line and hot gas line
■
Heating mode
m
3 to 30
3 to 30
3 to 30
■
Cooling mode
m
3 to 30
3 to 30
3 to 30
Sound power of outdoor unit
at rated heating output
(measurements with reference to EN 12102/
EN ISO 9614-2)
Weighted total sound power level
■
At A7
±
3 K
/W55
±
5 K
(max.)
dB(A)
61
61
61
■
At A7
±
3 K
/W55
±
5 K
in night mode
dB(A)
55
55
55
Energy efficiency class
to EU Regulation no.
811/2013
Heating, average climatic conditions
■
Low temperature applications (W35)
A
++
A
++
A
++
■
Medium temperature applications (W55)
A
++
A
++
A
++
Performance data
as per EU Regulation No.
811/2013 (average climatic conditions)
Low temperature applications (W35)
■
Energy efficiency
η
S
%
180
183
182
■
Rated heating output P
rated
kW
9.75
11.17
11.64
Medium temperature applications (W55)
■
Energy efficiency
η
S
%
132
131
134
■
Rated heating output P
rated
kW
9.67
10.83
11.98
Sound power level to ErP
Sound power level, outdoor unit
dB(A)
56
56
56
Specification
Specification
(cont.)
5790 931 GB
Appendix