Only approved bonded seals with proof of practicability in keeping with
building law may be used with suitable drains, e. g.:
n
for the wear classes A and AO:
in accordance with ETAG 022 T1
n
for the wear classes A, B and C:
in accordance with DiBt Rule list A, Part 2 of the DiBt and the test
principles for bonded sealing (PG AIV-F)
n
in acc. with DIN EN 14891:
"
Liquid-applied impermeable products for use below ceramic tiling
boded with adhesives
"
Information regarding the procedure can be found in the instructions for
use of the corresponding product.
2.3.3
Fire protection
Advantix shower channels and drains can both be fitted to be fire proof.
The R120 pipe lead-in can be used for this purpose in the floor con-
struction. In this way, a fire resistance time of up to 120 minutes can be
achieved.
Fig. 6: Example: Fire protection pipe lead-in
Mounting instruction of the R120 pipe lead-in see model 4923.5, Art.-
No. 491 673.
Permitted bonded seals
Product information
Advantix bathroom drain