3 Handling
3.1
Assembly information
3.1.1
Important note
Before assembly:
n
check if the drainage capacity of the drain is sufficient for the arising
water volume
Chapter 2.1.3 ‘Drainage capacity’ on page 7
n
check if the installation height of the drain corresponds with the
planned floor construction
n
ensure that the required connection line is installed with the neces-
sary incline to the planned installation location
n
if necessary, supply the required accessories
‘Required accessories’ on page 14
During assembly:
n
observe installation dimensions
n
decide whether or not a backflow seal is required in the insertion part
of the top
After assembly:
n
the drain flange must be fully lined with mortar
3.1.2
Installation dimensions
Ø100
Ø220
165
105
75
35
Ø50
Ø40
Fig. 7: Dimensional drawing model 4935.1
3.1.3
Tools and materials
n
if necessary, sealing cuff, clamping ring, fitting screws
n
Top with grate, if not included in scope of delivery
Required material
Handling
Advantix bathroom drain
16 from 25