3.3
Commissioning
3.3.1
Setting the flush
Programming the control can be carried out for 30 minutes after the
supply voltage is applied. The control returns to normal operation after
30 minutes – programming is now blocked. If the settings have to be
changed after this time, the control must be disconnected from the
power supply for at least 10 seconds.
The programming set required to program the device is not
included in the scope of delivery. It can be purchased sepa‐
rately as accessory.
„Optional accessories“ on page 15
Observe the following features during programming:
–
Only one value can be set per programming step.
–
The settings are retained, even if there is an interruption
in the power supply.
–
The programming process can be cancelled without a
change of the settings by holding the magnetic key in
front of the programming contact until no acoustic signal
has sounded for more than two seconds.
Requirements:
n
The revision shaft is open and the control can be accessed.
n
The control programming block is not active.
n
The programming set is available.
Remove the protective cap of the programming connection from the
control.
Programming block
Setting the flush volume
Handling
WC flush actuation
39 from 48
Содержание 8350.31