3.2
Assembly
3.2.1
Mounting the power pack
DANGER!
Danger due to electrical current
An electric shock can lead to burns and serious injury and
even death.
– Work on the electrics may only be carried out by trained
electricians.
– Always de-energise the connection line before work is
commenced.
Requirements:
n
A 230 V mains connection is available on site.
n
The installation position of the power pack complies with the require‐
ments in acc. with
„Installation position of the power pack“
.
n
The connection pipeline is de-energised.
Remove approx. 1 cm of the insulation on the connection pipeline.
Push the connection pipeline into the clamps.
Handling