Viega 8350.31 Скачать руководство пользователя страница 21

Score the revision shaft along the edge of the tiles with a knife.
Angle the knife to do this so that the cut is made flush to the surface

of the wall.

Cut the corners of the revision shaft vertically through to the wall

surface.

Bend out and pull down the sides of the revision shaft.
The edge of the revisions shaft must be flush with the wall surface.

Remove cistern cover.
Remove and keep the threaded bolts from the cistern cover.
Dispose of cistern cover.

Handling

WC flush actuation

21 from  48

Содержание 8350.31

Страница 1: ...on with WC flush plates Visign for Public 2 Visign for Style 11 12 and Visign for More 100 102 103 flush actuation via on site potential free contact Model Year built 8350 32 from 05 2012 en_INT WC fl...

Страница 2: ...WC flush actuation 2 from 48...

Страница 3: ...essories 15 3 Handling 17 3 1 Assembly information 17 3 1 1 Mounting conditions 17 3 1 2 Required material and tools 18 3 2 Assembly 19 3 2 1 Mounting the power pack 19 3 2 2 Preparing the installatio...

Страница 4: ...aintain this product This restriction does not extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the...

Страница 5: ...n Europe e g EN and or in Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national r...

Страница 6: ...r many Electrical approvals EN 60950 Electrical approvals EN 60335 Electrical approvals EN 61558 2 2 Safety advice DANGER Danger due to electrical current An electric shock can lead to burns and serio...

Страница 7: ...ch model is installed before mounting The following infor mation will help you to determine the model of the cistern installed Cistern 2H The revision shaft of this cistern is found at a height of app...

Страница 8: ...9 8 3 4 5 13 12 2 11 Fig 1 Scope of delivery 1 Bowden cable unit 2 holder for control for cistern 2H 3 holder for control for cistern 2L 4 power pack 230 V 5 connection cable external button 6 holder...

Страница 9: ...ume 3 4 litres If the external sensor e g a remote button on the handle offers two activation options the electronic actuation can be used to select between the large or small flush volume Input power...

Страница 10: ...rnal sensor e g a button or photo sensor Fig 3 Signal transmission from the control to the motor The control transmits the electronic signal to the drive unit Fig 4 The motor operates the Bowden cable...

Страница 11: ...be actuated at certain times with the Hygiene function Interval and flush volume will be set as required and saved by the con trol All settings remain saved during a power cut 2 4 4 System expansions...

Страница 12: ...ond external button One requires the following accessories to be able to connect an addi tional external sensor as shown Multiple sensors can be connected at the same time using the exten sion cable a...

Страница 13: ...of radio and cable sensors One requires the following accessories to be able to connect a radio controlled actuator alongside an external sensor as shown Multiple sensors can be connected at the same...

Страница 14: ...l need the following accessories The battery compartment can be connected for a redundant power supply using the adapter model 8355 91 The battery compartment is included in the adapter s scope of del...

Страница 15: ...ush 168 hours after the last use Hygiene flush volume The following settings are possible n Hygiene flush volume 3 litres factory setting n Hygiene flush volume 6 litres n Hygiene flush volume 9 litre...

Страница 16: ...required to change the flush setting or activate the Hygiene function It contains a connection cable with a program ming contact and a magnetic pin The programming contact is mounted behind the panel...

Страница 17: ...ional accessories on page 15 If necessary the power pack cable can be extended to a length of 4 75 metres two extension cables Optional accessories on page 15 X1 X2 X3 Fig 10 Installation position of...

Страница 18: ...s or protective pipes must be laid in the cistern before tiling is begun 3 1 2 Required material and tools The following material is required for mounting n a suitable flush plate Suitable manual flus...

Страница 19: ...se the connection line before work is commenced Requirements n A 230 V mains connection is available on site n The installation position of the power pack complies with the require ments in acc with I...

Страница 20: ...are marked accordingly Requirements n The cistern is fitted into the pre wall n If external sensors are to be connected the cables must be laid through to the cistern n The electrical connection is la...

Страница 21: ...all Cut the corners of the revision shaft vertically through to the wall surface Bend out and pull down the sides of the revision shaft The edge of the revisions shaft must be flush with the wall surf...

Страница 22: ...nting of the mechanism INFO Only for assembly of the flush plate on the top of cistern 2L Press the bow backwards from the mounting of the mechanism Turn the mechanism s lock by 90 in an anti clockwis...

Страница 23: ...actuation cistern 2H Requirements n The revision shaft is shortened in such a way that it is flush with the upper edge of the tiles n Mechanism bow and spacer are removed Close corner valve Loosen fle...

Страница 24: ...the panel into the cistern at an angle Align the right side of the holding panel with the shaft frame of the cistern The hook on the right side of the holding panel must be positioned on the projecti...

Страница 25: ...k wall Push the drive unit onto the holding panel The drive unit must be secure in the guiding rail If the holding panel for the drive unit is mounted remove holding panel Push the Bowden cable unit o...

Страница 26: ...y must always be connected last to ensure that all of the connected components function INFO Mounting is much easier if the plug is inserted into the control outside of the cistern Connect the red plu...

Страница 27: ...ttings for the control can also already be made at this point The programming set is easier to connect if the control is not yet installed in the cistern Chapter 3 3 Com missioning on page 39 Insert t...

Страница 28: ...Connect the flexible hose onto the filling valve Open corner valve Insert spacer Mounting the battery compartment optional Handling WC flush actuation 28 from 48...

Страница 29: ...nt through the large opening into the holder Push the battery compartment into the smaller opening The battery compartment must be clicked into place directly behind the cover in the holder Hang the m...

Страница 30: ...m is locked As the next step fitting of the flush plate as per the instruc tion manual supplied 3 2 4 Mounting the flush actuation cistern 2L Requirements n The revision shaft is shortened in such a w...

Страница 31: ...size 19 Open the corner valve for a few seconds to rinse the pipe Re close corner valve If the holding panel is not mounted on the Bowden cable unit posi tion the holding panel Mounting the drive uni...

Страница 32: ...the Bowden cable unit onto the drain valve from the left The Bowden cable unit must be felt to click into place on the drain valve Position holder with recess on the corner valve Mounting the holder f...

Страница 33: ...mponents function INFO Mounting is much easier if the plug is inserted into the control outside of the cistern Connect the red plug of the Bowden cable unit motor to the red connection of the control...

Страница 34: ...the control is not yet installed in the cistern Chapter 3 3 Com missioning on page 39 Insert the control into the bracket in the cistern Fit the cable into the upper part of the cistern and fix with t...

Страница 35: ...e How to install the mechanism depends on whether the flush plate is to be fitted to the front or top of the cistern Hang the mechanism in the bow of the drain valve Mounting the battery compartment o...

Страница 36: ...recesses of the cistern Turn the mechanism s lock by 90 in a clockwise direction The mechanism is locked Hang the mechanism in the bow of the drain valve Horizontal installation flush plate on the top...

Страница 37: ...0 in a clockwise direction The mechanism is locked As the next step fitting of the flush plate as per the instruc tion manual supplied 3 2 5 Connecting external sensors NOTICE Damage to property due t...

Страница 38: ...cable model 8355 90 available Connect the contact to actuate the small flush volume between the green 1 and yellow cable 3 Connect the contact to actuate the large flush volume between the green 1 and...

Страница 39: ...ries on page 15 Observe the following features during programming Only one value can be set per programming step The settings are retained even if there is an interruption in the power supply The prog...

Страница 40: ...following values can be set by removing the magnetic key Remove magnetic key after Setting 1st acoustic signal Flush volume small 3 l and large 4 5 l 2nd acoustic signal Flush volume small 3 l and la...

Страница 41: ...h to use the Hygiene function you must program the following settings The flush volume for the Hygiene function can only be selected if the Hygiene function has been activated by choosing a flushing i...

Страница 42: ...amming block is not active Programming block on page 39 n The programming set is available Remove the protective cap of the programming connection from the control Connect the cable from the programmi...

Страница 43: ...the magnetic key Remove magnetic key after Setting 8th acoustic signal Hygiene flush volume 3 l fac tory setting if Hygiene is active 9th acoustic signal Hygiene flush volume 6 l 10th Acoustic signal...

Страница 44: ...can be accessed n The control programming block is not active Programming block on page 39 n The programming set is available n The Hygiene interval is set Remove the protective cap of the programmin...

Страница 45: ...removing the magnetic key Remove magnetic key after Setting 4th acoustic signal Hygiene flush function OFF factory setting 5th acoustic signal Hygiene flush performed 24 hours after the last flush 6t...

Страница 46: ...ck control not made Create plug connection Con necting the control on page 26 Plug connection drive unit control not made Create plug connection Con necting the control on page 26 WC flush runs throug...

Страница 47: ...a battery compartment for redundant power supply Requirements n The flush plate has been removed n The mechanism has been removed compare Chapter 3 2 2 Pre paring the installation on page 20 n Free a...

Страница 48: ...re the battery compartment with a cable tie Replace and lock mechanism Mount flush plate according to manual 3 6 Disposal Separate the product and packaging materials e g paper metal plastic or non fe...