background image

2 Product information

2.1

Intended use

2.1.1

Areas of use

NOTICE! 

Risk of damage due to unsuitable liquids.
To avoid damaging the drain, only introduce the following
liquids:

– Liquids with a pH-value higher than 4
– typical household water with a maximum temperature of

95 °C

The Multiplex Trio drain°/overflow is a combined inlet, drain and over-
flow with odour trap for bathtubs with a 52 mm drain hole. The inlet
flows through the overflow opening.

The drain / overflow is suitable for standard bathtubs with the drain on
the head end.

Detailed information regarding all bathtub models and the corre-
sponding Viega drains / overflows can be found in the catalogue or on
the Internet.

An equipment set with rotatable rosette and valve cone must be pur-
chased separately.

2.2

Product description

2.2.1

Overview

The following components are included in the scope of delivery of the
Multiplex Trio drain / overflow:

Product information

Multiplex Trio drain/overflow functional unit

6 from  20

Содержание 6161.52

Страница 1: ...for water inlet through the overflow unit Model Year built 6161 52 from 06 2015 en_INT Multiplex Trio drain overflow functional unit Instructions for Use ...

Страница 2: ...Multiplex Trio drain overflow functional unit 2 from 20 ...

Страница 3: ...information 11 3 1 1 Mounting conditions 11 3 1 2 Installation dimensions 12 3 1 3 Required tools and materials 12 3 2 Assembly 12 3 2 1 Mounting overflow 12 3 2 2 Mounting the drain 14 3 2 3 Connecting overflow and drain 14 3 2 4 Connecting the wastewater system 15 3 2 5 Connecting the inlet 16 3 2 6 Mounting equipment set 17 3 2 7 Leakage test 18 3 2 8 Demounting rotatable rosette 18 3 3 Control...

Страница 4: ...ot extend to possible operating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advisory texts are set aside from the remainder of the text and are labelled with the relevant pictographs DANGER This symbol warns against possible life threatening injury WARNING T...

Страница 5: ...n Germany e g DIN DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The pertinent national laws stand ards regulations and guidelines as well as other technical guidelines have priority over German European guidelines in this manual The information is not binding for other countri...

Страница 6: ... drain hole The inlet flows through the overflow opening The drain overflow is suitable for standard bathtubs with the drain on the head end Detailed information regarding all bathtub models and the corre sponding Viega drains overflows can be found in the catalogue or on the Internet An equipment set with rotatable rosette and valve cone must be pur chased separately 2 2 Product description 2 2 1...

Страница 7: ...pipe 10 Bowden cable 11 sleeve 12 inlet adapter 13 overflow unit 14 profile seal 15 additional seal for steel bathtubs 16 supply flange 17 fixing screw 18 mounting aid 2 2 2 Technical data Drainage capacity at an accumu lation height of 300 mm 0 87 l s Overflow capacity at an accumu lation height of 60 mm 0 63 l s Product information Multiplex Trio drain overflow functional unit 7 from 20 ...

Страница 8: ...To ensure that no bath water flows back into the drinking water system a pipe interrupter must be installed e g the connection set with con cealed pipe interrupter DN 20 in acc DIN EN 1717 model 6161 86 Equipment sets As this product is a the functional unit without rotatable rosette and valve cone you require an equipment set to enable complete mounting Equipment sets contain a rotatable rosette ...

Страница 9: ...e overflow can be increased by 5 cm with the equipment set The equipment set contains a rotatable rosette a fixing flange a valve cone a fixing screw a flange cover and a mounting aid for the drain of the functional unit Equipment set Multiplex Trio Visign MT9 Model 6170 0 Optional accessories Product information Multiplex Trio drain overflow functional unit 9 from 20 ...

Страница 10: ...ssible to extend the odour trap below the bathtub in the case of bathtubs with a very thick floor The extension set model 6161 7 is available for such cases Product information Multiplex Trio drain overflow functional unit 10 from 20 ...

Страница 11: ...that no bath water flows back into the drinking water system a pipe interrupter must be installed in the pipeline between the shut off fitting and the bathtub inlet The following schematic diagram shows what this should look like Fig 2 Mounting scheme with pipe interrupter It is important that the pipe interrupter is mounted at least 150 mm above the top edge of the bathtub Observe the local stand...

Страница 12: ... scope of delivery n spanner SW 26 The following material must be purchased separately and must be avail able during mounting n pipe interrupter e g the pipe interrupter set for connection of the inlet n Connection set for the connection of the inlet e g the pipe inter rupter set n equipment set 3 2 Assembly 3 2 1 Mounting overflow Proceed as follows to the mounting of the overflow Tool Material H...

Страница 13: ...ush the rubber sleeve onto the overflow unit pipe until the lower edge is flush with the edge of the overflow pipe Fit inlet flange into the overflow unit Screw in fixing screw and tighten hand tight On the hexagon of the mounting aid there is a groove which must be positioned on the lip of the fixing screw Handling Multiplex Trio drain overflow functional unit 13 from 20 ...

Страница 14: ... double seal through the drain hole Fit the valve top in the double seal INFO The cross shaped structures of the drain units and the valve top must be positioned parallel on top of each other to ensure the full drainage capacity Place the fixing screw in the drain unit and tighten using the mounting aid 3 2 3 Connecting overflow and drain After the overflow and the drain have been mounted you must...

Страница 15: ...itions where the drain and the overflow should be con nected Maintain an insertion depth of at least 15 mm Cut the overflow pipe to the marked length and if necessary deburr Push the top end of the overflow pipe into the rubber sleeve Maintain an insertion depth of at least 15 mm Push the union nut sliding ring and seal onto the bottom end of the drain elbow Screw the union nut on the drain unit 3...

Страница 16: ...rap in such a way that the drain elbow can be con nected to the wastewater pipe Turn the drain at the joints until the required position has been reached Push wastewater pipe in the drain elbow 3 2 5 Connecting the inlet Proceed as follows to connect the water inlet to the overflow unit Requirements n A connection set e g the pipe interrupter set is available n A pipe interrupter is installed in t...

Страница 17: ...sert the inlet adapter into the overflow unit The inlet adapter must click into place in the overflow unit with a noticeable clicking sound 3 2 6 Mounting equipment set The equipment set is not included in the scope of delivery and must be purchased separately To avoid damage to the rosette and valve cone only mount the equip ment set after finishing all other work on the building site Proceed as ...

Страница 18: ...ter with union nut 3 2 7 Leakage test The leakage test is only carried out as a visual inspection Check the points marked in the following drawing with particular care Check drain fitting for visible leaks 3 2 8 Demounting rotatable rosette If the rotatable rosette on the overflow is to be removed proceed as fol lows to prevent damaging the rosette and the flange cover Remove the rotatable rosette...

Страница 19: ...o open or close the drain Turn rotatable rosette to the left ð The drain closes itself Turn rotatable rosette to the right ð The drain opens itself There is a regulator for the water jet on the underside of the rotatable rosette Proceed as follows to adjust the water jet Setting the water inlet direction Handling Multiplex Trio drain overflow functional unit 19 from 20 ...

Страница 20: ... agent can be used for regular care and prevention of lime scale on the rotatable rosette and valve cone Under no circumstances should scouring agent or scratching objects be used Strong stains even around the drain unit and the siphon can be removed using typical household cleaner It should be noted that the cleaning agent should be rinsed off after the prescribed soaking time There should be no ...