2.3.3

Technical data

Nominal width [DN]

40 / 50

Material

Plastic odour trap
Shower channel profile from stainless steel

1.4301

Drainage capacity

Ä

 Chapter 2.2.3 „Drainage capacity“

on page 7

Dimensions and installa‐

tion height

Ä

 Chapter 3.1.3 „Installation dimen‐

sions“ on page 13

Water seal level

25 mm

Load class

K= 300 kg

2.4

Information for use

2.4.1

Sealing

To protect against moisture penetration, apply sealing foils, which are to

be processed in liquid state, directly below the tiles on screed and

walls. The determination of the stress class and the underground as well

as the selection of the suitable bonded sealing must be carried out in

compliance with the valid standards and regulations, see: 

Ä

 „Regula‐

tions from section: Sealing“ on page 6

.

Bonded sealing

Product information

Advantix Cleviva shower channel base unit (reconstruction model)

9 from  30

Содержание 4981.81

Страница 1: ...for bonded sealing tiled shower Model Year built 4981 81 from 03 2019 en_INT Advantix Cleviva shower channel base unit reconstruction model Instructions for Use...

Страница 2: ...Advantix Cleviva shower channel base unit reconstruction model 2 from 30...

Страница 3: ...data 9 2 4 Information for use 9 2 4 1 Sealing 9 2 5 Required accessories 11 3 Handling 12 3 1 Assembly information 12 3 1 1 Important note 12 3 1 2 Tools and materials 12 3 1 3 Installation dimensio...

Страница 4: ...perating instructions The installation of Viega products must take place in accordance with the general rules of engineering and the Viega instructions for use 1 2 Labelling of notes Warning and advis...

Страница 5: ...DVGW Some passages in the text may refer to technical codes in Europe Germany These should serve as recommendations in the absence of corresponding national regulations The relevant national laws sta...

Страница 6: ...for stress classes A and AO ETAG 022 T1 Approved bonded sealings with proof of practicability in keeping with building law for stress classes A B and C DIBt Bauregelliste A Teil 2 des DIBt und Pr fgru...

Страница 7: ...on see Regulations from section Media on page 6 n The short term temperature of the wastewater may reach up to 95 C The temperature must be considerably lower in constant operation n The pH value must...

Страница 8: ...mm with millimetre precision 2 3 2 Overview of the components Fig 1 Components and scope of delivery 1 height adjustment piece 2 Site protection composite wood 3 Sieve insert 4 Sealing collar 5 Site p...

Страница 9: ...mation for use 2 4 1 Sealing To protect against moisture penetration apply sealing foils which are to be processed in liquid state directly below the tiles on screed and walls The determination of the...

Страница 10: ...east 50 mm must be used n The screed must be laid at a minimum incline of 1 2 n The installation must be carried out properly in acc with the mounting instructions and the manufacturer s information 1...

Страница 11: ...the shower channel base unit a shower channel insert model 4981 50 or 4981 60 and a shower channel profile model 4981 30 4981 31 or 4981 32 are also required Product information Advantix Cleviva show...

Страница 12: ...ed before mounting n The dimensions of slots and recesses must be in compliance with the regulations from section Regulations from section Important notes on page 7 During assembly n Observe installat...

Страница 13: ...3 1 3 Installation dimensions Fig 3 Dimensions of base unit basic model Shower channel basic model with one base unit Handling Advantix Cleviva shower channel base unit reconstruction model 13 from 30...

Страница 14: ...ng tiler Determine the screed height H The installation height is 70 155 mm Shorten the dimension X on the mounting flange X 155 mm H Deburr the mounting flange INFO The height can be extended using a...

Страница 15: ...rt the profile seal Apply a coat of lubricant for plastic pipes to the inside of the profile seal Push the flange into the odour trap as far as it will go Handling Advantix Cleviva shower channel base...

Страница 16: ...The flange can be rotated around 360 Turn the transition to eccentrically offset the drain by up to 8 5 mm d NN Handling Advantix Cleviva shower channel base unit reconstruction model 16 from 30...

Страница 17: ...mm art no 791 650 3 mm art no 790 448 Shorten the connection pipe as required Push the sliding ring and the wedge seal onto the connection pipe Position the wedge seal on the groove Screw the connecti...

Страница 18: ...Secure the drain INFO Use fixing set article no 497 003 as an option Handling Advantix Cleviva shower channel base unit reconstruction model 18 from 30...

Страница 19: ...wall Interval to wall odour trap model 4981 11 4981 81 interval A B C Minimum X 27 mm 16 mm 14 mm Maximum Y 36 mm 25 mm 23 mm Cut the side of the reinforcement area on the wall with a blade The floori...

Страница 20: ...when pressure is applied Inform the subsequent workers that the shower channel must be fully lined and that there must be no hollow spaces The screed and floor tiles must be laid at an incline of 1 2...

Страница 21: ...ded sealing Remove and dispose of the site protection The flange must be clean and free from material residues Grease the sealing element Clip the sealing collar into the flange Check that the sealing...

Страница 22: ...generously onto the screed and the flange Push the sealing into the bonded sealing which is still in the liquid state without wrinkles Once the first layer has dried apply the second layer of the bon...

Страница 23: ...one Profile length Shortening range 800 mm 600 800 mm 1000 mm 800 1000 mm 1200 mm 1000 1200 mm Offset between shower channel profile and tile In the drain zone the shower channel profile can be shorte...

Страница 24: ...the shower channel profile at right angles and deburr Alternatively the shower channel profile can be shortened using an electric metal slitting disc or a speed restricted angle grinder with suitable...

Страница 25: ...mine the flooring height H INFO For fault free drainage Viega recommends laying the floor covering 1 2 mm higher than the shower channel profile Due to the stepless shortening of the top an installati...

Страница 26: ...ension X 30 mm H Shorten dimension X along the cutting aid and deburr Unroll the butyl tape and cut to size Stick the butyl tape centrally on the underside of the shower channel profile NN 9 Handling...

Страница 27: ...channel profile and the height adjustment piece Align the shower channel profile and the height adjustment piece horizontally n The shower channel profile can be radially rotated by max 10 mm with a...

Страница 28: ...y positioned by 7 5 mm After alignment fasten the height adjustment piece with tile adhe sive Fit the insert Two insert variants are available n Inlet opening double model 4981 50 n Inlet opening sing...

Страница 29: ...t or abrasive objects Strong stains even around the drain unit and the siphon can be removed using typical household cleaner Rinse the detergent very thor oughly with clear water after the prescribed...

Страница 30: ...nt 3 4 Disposal Separate the product and packaging materials e g paper metal plastic or non ferrous metals and dispose of in accordance with valid national legal requirements Handling Advantix Cleviva...

Отзывы: