Can be installed only in front of a plastered wall or a prefab‐
ricated wall.
The distances to the shower channel profile depend on the positioning
of the odour trap.
n
X = minimum interval to wall
n
Y = maximum interval to wall
Interval to wall, odour trap model 4981.11 / 4981.81
interval
A
B
C
Minimum X
27 mm
16 mm
14 mm
Maximum Y
36 mm
25 mm
23 mm
Cut the side of the reinforcement area on the wall with a blade.
The flooring height (bonded s ad tiles) must not
exceed 30 mm.
Wall mounting
$
#
"
Fig. 4: Interval to wall, odour trap model
4981.11 / 4981.81
9
:
Handling
Advantix Cleviva shower channel base unit (reconstruction model)