![Viega 4981.81 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/viega/4981-81/4981-81_instructions-for-use-manual_1016560007.webp)
Regulations from section: Important notes
Scope / Notice
Regulations applicable in Ger‐
many
Dimensions of slots and recesses EN 1996
2.2
Intended use
2.2.1
Areas of use
The shower channel is used in the bathroom as a drain for a floor-level
shower. It is designed for small to medium volumes of water, which
occur in e.g. residential building.
Technical information, see
Chapter 2.3.3 „Technical data“ on page 9
2.2.2
Media
The shower channel is intended for draining of household-type waste‐
water in constant operation, see
„Regulations from section: Media“
n
The short-term temperature of the wastewater may reach up to
95° C. The temperature must be considerably lower in constant
operation.
n
The pH value must be higher than 4 but lower than 10.
It is not permitted to introduce wastewater which would damage the
product material.
2.2.3
Drainage capacity
The water seal level is 25 mm.
Construction height 70 mm
Accumula‐
tion height
10 mm
20 mm
Sieve insert
with
does not
include
with
does not
include
Grate insert
double slit
0.50 l/s
0.60 l/s
0.55 l/s
0.65 l/s
Grate insert
straight slit
0.40 l/s
0.50 l/s
0.45 l/s
0.55 l/s
Product information
Advantix Cleviva shower channel base unit (reconstruction model)
7 from 30