Insert sealing ring.
The sealing ring must lie in the groove between the flange and the
screw holes.
INFO! The Viega sealing collar has two differently coated sides.
One side is coated with bitumen and the other side with EPDM. If
the additional sealing takes place with bitumen sealing lanes, the
sealing collar must be used with the bitumen side facing
upwards. If EPDM sealing lanes are used, the EPDM side must
face upwards.
Position the sealing collar on the drain.
The screw holes must be visible through the recesses.
Position the sealing flange on the sealing collar in such a way that
the screw holes are visible.
Screw the sealing flange together tightly with the drain.
The fixing screws of the clamping ring may only be screwed into the
screw holes of the drain.
ð
The drain is sealed and the remaining sealing collars can be
laid.