Use suitable fixing material to fastened the base to the support pro-
file.
Further see
Chapter 3.3.2 „Connecting the flush valve to the pipe-
3.3.2
Connecting the flush valve to the pipeline
n
For mounting in a ring installation, mount the flush valve with a main-
tenance shut-off directly at the T-piece with the water flow.
n
For mounting in a series inistallation, mount and connect the flush
valve as the last consumer.
For maintenance purposes, use the following shut-off elements:
n
Wall-mounted assembly: Easytop ball valve model 2270.1, DN 25 -
EAN 587048 and screw fitting model 2263 - EAN 320256
n
Concealed mounting: Easytop slanted seat valve model 2237.1, DN
20 - EAN 457143
n
Alternative for concealed mounting: Easytop basic valve model
2137.09, DN 20 - EAN 624217
For connecting the siphon to the drainage system, for
example the following rules and standards are applicable:
–
DIN EN 12056:2001
–
DIN 1986-100:2008:05
Installation variants
Maintenance shut-off
Connecting the supply and disposal lines
Handling
Flush valve universal
34 from 62