background image

 

 

CMOR Dome

 

 

Videoswitch Page 

9  

Vc607a.doc 

 

4 Menus 

4.1 Menu Navigation 

4.1.1 Entering 

Menu 

Different keyboards have different ways of entering the menu system of a dome. Refer to  
specific keyboard manual for details. 

Common examples are: 

 

Videoswitch Vi-K2 

Press DOME then press MENU 

 

Videoswitch Vi-K3 

Press and hold ALT then press DOME MENU 

 

BBV (TX400) 

 

Press and hold SHIFT then press 1 

 

Pelco (KBD400A) 

Enter 95 then press and hold PRESET key 

 

Dedicated Micro DS2 

Press and hold * 8,8,910,10,2 

4.1.2 Moving 

cursor 

Once in the menu, the joystick may be used for LEFT, RIGHT, UP and DOWN control of the 
cursor. On a Videoswitch keyboard, the cursor keys can also be used. 

 

UP 

 

 

move the cursor up, or change a value 

 

DOWN   

 

move the cursor down, or change a value 

 

RIGHT   

 

move the cursor right, or enter a sub-menu 

  LEFT 

move the cursor left, or exit a sub-menu. When editing a 
title, you may need to go LEFT several times to exit 

4.1.3 Select 

Use of Select is not necessary – if there is no joystick movement and no key is pressed for 5 
seconds (programmable), the dome will automatically issue a select command, for example 
to save a preset or mask. 

If you wish to issue a Select command to avoid having to wait, the required key depends on 
the type of keyboard.  

Common examples are: 

 

Videoswitch Vi-K2 

Press OK 

 

Videoswitch Vi-K3 

Press OK 

 

BBV (TX400) 

 

Press 1 

 

Pelco (KBD400A) 

Enter 96 then press and hold PRESET key 

 

DS2 

   Press 

Preset,10, then preset number e.g.1,2 

4.1.4 Cancel 

Use of Cancel is not essential, but can be used to quit a preset without setting it. This also 
depends on the type of keyboard.  

Common examples are: 

 

Videoswitch Vi-K2 

Press BACK or WASH 

 

Videoswitch Vi-K3 

Press ALT and ESC 

 

BBV TX400 

 

Press WASH 

 

Pelco   

 

-  

Enter 97 then press and hold PRESET key 

Содержание CMOR D4

Страница 1: ...Options Document Reference Date Firmware Vc607a doc 14 12 2012 From Vc006 210 Videoswitch Telephone 01252 851510 Ocean House Redfields Industrial Park Fax 01252 851296 Redfields Lane Church Crookham...

Страница 2: ...Auto Protocol and Auto Baud 7 3 1 2 Address 7 3 1 3 Clear Address 8 3 1 4 Reset Address 8 3 1 5 Termination 8 4 Menus 9 4 1 Menu Navigation 9 4 1 1 Entering Menu 9 4 1 2 Moving cursor 9 4 1 3 Select 9...

Страница 3: ...6 1 2 4 Preset Focus Mode 16 4 6 1 2 5 Zoom Limit 16 4 6 1 2 6 Backlight compensation 16 4 6 1 2 7 Noise Reduction 17 4 6 1 2 8 Wide Dynamic Range 17 4 6 1 2 9 High Resolution Mode 17 4 6 1 2 10 Image...

Страница 4: ...1 5 1 3 Power requirements 21 5 1 4 Physical and Environmental 21 5 2 Vi PSU 1A Power Supply 21 5 2 1 Power 21 5 2 2 Alarm Module Selection 21 5 2 3 Physical and Environmental 21 5 2 4 Safety 21 5 3 V...

Страница 5: ...plate Fix the mounting plate to the wall or corner or pole adaptor using four screws A of adequate size and strength to support the weight of the dome Fit the umbilical cable entering either through t...

Страница 6: ...lift it using lamps and place the dome support plate A onto the dome support cradle B Note that the curved side of the support plate goes to the back Rotate the locking ring C counter clockwise to loc...

Страница 7: ...the mounting bracket using the screws provided Then attach the dome and umbilical cable in the same was as described in previous paragraphs 1 1 3 and 1 1 4 Slide down the protective cup 1 3 Vi B4 Swan...

Страница 8: ...a doc 1 4 Vi B5 Corner Adaptor Use this in conjunction with the Vi B2 wall bracket to mount the dome on the corner of a building 1 5 Vi B6 Pole Adaptor Use this in conjunction with the Vi B2 wall brac...

Страница 9: ...in a weatherproof box that may be mounted externally or internally Never apply 24AC to the standard DC dome 2 1 Fixing power supply to a wall Fit the optional alarm module A into the power supply usi...

Страница 10: ...nal dual camera version only GND White Coax screen dual camera version only CAM1 Black Coax signal GND Black Coax screen RS485 A WHITE RS485 B ORANGE 24V RED 0V BLACK and Cable screen 2 2 3 Connection...

Страница 11: ...l if an alarm module is being used 3 1 2 Address If you are using the dome via BBV up the coax control there is no need to set the address and this section can be ignored In the case of RS485 control...

Страница 12: ...you do need to turn the termination of a dome OFF enter the dome Setup menu and turn the termination off If you are using a star expander eg Videoswitch Vi E2 to drive multiple domes all domes should...

Страница 13: ...r right or enter a sub menu LEFT move the cursor left or exit a sub menu When editing a title you may need to go LEFT several times to exit 4 1 3 Select Use of Select is not necessary if there is no j...

Страница 14: ...he dome 4 2 Menu Summary Login Display Information screens System Status Alarms Camera Coax Date Time Enter date time Daylight saving Display Position on screen Row Column Title Title Display Position...

Страница 15: ...mode Preset focus mode Backlight compensation Noise reduction Wide dynamic range High resolution mode Image stabiliser Night settings lamps on Shutter speed Exposure compensation Joystick focus mode P...

Страница 16: ...ent levels The Installer password gives access to the whole menu Supervisor gives access to some items and User gives access to fewest items When all three passwords have been set i e to something oth...

Страница 17: ...s option determines whether or not the preset titles are displayed while a tour is in progress 4 4 Setup 4 4 1 Dome Address When using RS485 control the dome address is set or cleared in this menu To...

Страница 18: ...t 4 4 5 5 Clear everything To clear the configuration presets and tours enter this menu use UP to select YES and go LEFT to exit 4 4 5 6 Reboot To restart the dome equivalent to power cycling enter th...

Страница 19: ...s to come on 4 5 3 Off level hysteretic The IR lamps are turned off when the light level rises to the ON level plus this hysteresis value The default is 125 4 5 4 Auto lamp delay Set the time in secon...

Страница 20: ...0 4 6 1 1 6 Backlight compensation Backlight compensation can be turned ON or OFF 4 6 1 1 7 Noise Reduction 4 6 1 1 8 Wide Dynamic Range 4 6 1 1 9 High Resolution Mode 4 6 1 1 10 Image Stabiliser 4 6...

Страница 21: ...trol from the joystick keyboard 4 7 1 Restore Mode Preset Tours Set this option if you want the dome to revert to a TOUR or PRESET 1 after a specified period in seconds of inactivity If the restore mo...

Страница 22: ...e to go to Press SELECT or wait 10 seconds to set the position 4 7 7 Iris key usage The Iris control keys on the keyboard may be used to either alter the Exposure compensation Brighten or darken the i...

Страница 23: ...y be included in the tour Clear Clear the tour of all presets Cancel Use LEFT to exit without changing the tour 4 9 1 1 3 Clear Tour 4 9 1 1 4 Title If you want a title to be displayed when you select...

Страница 24: ...DVR rather than the alarm option the following settings have no effect 4 11 1 Enable Alarms 4 11 2 Alarm override time 4 11 3 New alarm dwell When a new alarm occurs the dome will go to the correspon...

Страница 25: ...ns Weight 252 4mm x 485mm x 225 8mm HxWxD 4 32kg Dimensions Weight Boxed 385mm x 300mm x 300mm HxWxD 4 72kg 5 2 Vi PSU 1A Power Supply 5 2 1 Power Input 100 to 240 Vac 50 60Hz Output 24Vdc 2 5A 5 2 2...

Страница 26: ...acket 5 4 4 Vi B3 Pendant bracket 5 4 5 Vi B6 Pole mount bracket 5 4 6 Vi B7 Dome adaptor 5 4 7 Vi B8 Ceiling Mount Kit 5 4 8 Cables Longer 10metres cable are available where longer runs are required...

Страница 27: ...CMOR Dome Videoswitch Page 23 Vc607a doc Serial Number of dome Notes Notes...

Страница 28: ...CMOR Dome Videoswitch Page 24 Vc607a doc...

Отзывы: