background image

 

 

CMOR Dome

 

 

Videoswitch Page 

8  

Vc607a.doc 

 

3.1.3 Clear 

Address 

If the address of a dome has been set but needs changing, you either need to 

 

Communicate with it using its currently set camera address or  

 

Use up-the-coax control.  

Enter the 

Address

 menu, then the the 

Clear Address

 option to delete the address. The 

dome will then respond to all addresses again. 

3.1.4 Reset 

Address 

If  you wish to clear the addresses of 

all

 connected domes, do the following: 

Issue five 

SET Preset 90 

commands in succession, not more than 5 seconds apart. This 

will reset the dome address of 

all connected domes.

 

 

3.1.5 Termination 

Termination of the RS485 in the dome is normally set ON. 

If you do need to turn the termination of a dome OFF, enter the dome 

Setup

 menu and turn 

the termination off. 

 

If you are using a star expander (eg. Videoswitch Vi-E2) to drive multiple domes all 
domes should be have termination ON. This is the recommended method of 
connecting to multiple domes. 

 

If you are using an alarm module, termination in the dome should also always be 
ON. 

 

If you are daisy-chaining domes without alarm modules, for all except the last in the 
daisy chain, you will need to turn the termination OFF. The dome at the end of the 
daisy chain must have its termination ON.  

  If you are daisy-chaining domes with Vi-AL1A alarm modules, make sure the 

termination of all domes is ON. The Vi-AL1A alarm module always terminates the 
RS485.However, it provides an active output which regenerates the RS485 signal, 
so use this to connect to the next dome in the chain.  

 

Содержание CMOR D4

Страница 1: ...Options Document Reference Date Firmware Vc607a doc 14 12 2012 From Vc006 210 Videoswitch Telephone 01252 851510 Ocean House Redfields Industrial Park Fax 01252 851296 Redfields Lane Church Crookham...

Страница 2: ...Auto Protocol and Auto Baud 7 3 1 2 Address 7 3 1 3 Clear Address 8 3 1 4 Reset Address 8 3 1 5 Termination 8 4 Menus 9 4 1 Menu Navigation 9 4 1 1 Entering Menu 9 4 1 2 Moving cursor 9 4 1 3 Select 9...

Страница 3: ...6 1 2 4 Preset Focus Mode 16 4 6 1 2 5 Zoom Limit 16 4 6 1 2 6 Backlight compensation 16 4 6 1 2 7 Noise Reduction 17 4 6 1 2 8 Wide Dynamic Range 17 4 6 1 2 9 High Resolution Mode 17 4 6 1 2 10 Image...

Страница 4: ...1 5 1 3 Power requirements 21 5 1 4 Physical and Environmental 21 5 2 Vi PSU 1A Power Supply 21 5 2 1 Power 21 5 2 2 Alarm Module Selection 21 5 2 3 Physical and Environmental 21 5 2 4 Safety 21 5 3 V...

Страница 5: ...plate Fix the mounting plate to the wall or corner or pole adaptor using four screws A of adequate size and strength to support the weight of the dome Fit the umbilical cable entering either through t...

Страница 6: ...lift it using lamps and place the dome support plate A onto the dome support cradle B Note that the curved side of the support plate goes to the back Rotate the locking ring C counter clockwise to loc...

Страница 7: ...the mounting bracket using the screws provided Then attach the dome and umbilical cable in the same was as described in previous paragraphs 1 1 3 and 1 1 4 Slide down the protective cup 1 3 Vi B4 Swan...

Страница 8: ...a doc 1 4 Vi B5 Corner Adaptor Use this in conjunction with the Vi B2 wall bracket to mount the dome on the corner of a building 1 5 Vi B6 Pole Adaptor Use this in conjunction with the Vi B2 wall brac...

Страница 9: ...in a weatherproof box that may be mounted externally or internally Never apply 24AC to the standard DC dome 2 1 Fixing power supply to a wall Fit the optional alarm module A into the power supply usi...

Страница 10: ...nal dual camera version only GND White Coax screen dual camera version only CAM1 Black Coax signal GND Black Coax screen RS485 A WHITE RS485 B ORANGE 24V RED 0V BLACK and Cable screen 2 2 3 Connection...

Страница 11: ...l if an alarm module is being used 3 1 2 Address If you are using the dome via BBV up the coax control there is no need to set the address and this section can be ignored In the case of RS485 control...

Страница 12: ...you do need to turn the termination of a dome OFF enter the dome Setup menu and turn the termination off If you are using a star expander eg Videoswitch Vi E2 to drive multiple domes all domes should...

Страница 13: ...r right or enter a sub menu LEFT move the cursor left or exit a sub menu When editing a title you may need to go LEFT several times to exit 4 1 3 Select Use of Select is not necessary if there is no j...

Страница 14: ...he dome 4 2 Menu Summary Login Display Information screens System Status Alarms Camera Coax Date Time Enter date time Daylight saving Display Position on screen Row Column Title Title Display Position...

Страница 15: ...mode Preset focus mode Backlight compensation Noise reduction Wide dynamic range High resolution mode Image stabiliser Night settings lamps on Shutter speed Exposure compensation Joystick focus mode P...

Страница 16: ...ent levels The Installer password gives access to the whole menu Supervisor gives access to some items and User gives access to fewest items When all three passwords have been set i e to something oth...

Страница 17: ...s option determines whether or not the preset titles are displayed while a tour is in progress 4 4 Setup 4 4 1 Dome Address When using RS485 control the dome address is set or cleared in this menu To...

Страница 18: ...t 4 4 5 5 Clear everything To clear the configuration presets and tours enter this menu use UP to select YES and go LEFT to exit 4 4 5 6 Reboot To restart the dome equivalent to power cycling enter th...

Страница 19: ...s to come on 4 5 3 Off level hysteretic The IR lamps are turned off when the light level rises to the ON level plus this hysteresis value The default is 125 4 5 4 Auto lamp delay Set the time in secon...

Страница 20: ...0 4 6 1 1 6 Backlight compensation Backlight compensation can be turned ON or OFF 4 6 1 1 7 Noise Reduction 4 6 1 1 8 Wide Dynamic Range 4 6 1 1 9 High Resolution Mode 4 6 1 1 10 Image Stabiliser 4 6...

Страница 21: ...trol from the joystick keyboard 4 7 1 Restore Mode Preset Tours Set this option if you want the dome to revert to a TOUR or PRESET 1 after a specified period in seconds of inactivity If the restore mo...

Страница 22: ...e to go to Press SELECT or wait 10 seconds to set the position 4 7 7 Iris key usage The Iris control keys on the keyboard may be used to either alter the Exposure compensation Brighten or darken the i...

Страница 23: ...y be included in the tour Clear Clear the tour of all presets Cancel Use LEFT to exit without changing the tour 4 9 1 1 3 Clear Tour 4 9 1 1 4 Title If you want a title to be displayed when you select...

Страница 24: ...DVR rather than the alarm option the following settings have no effect 4 11 1 Enable Alarms 4 11 2 Alarm override time 4 11 3 New alarm dwell When a new alarm occurs the dome will go to the correspon...

Страница 25: ...ns Weight 252 4mm x 485mm x 225 8mm HxWxD 4 32kg Dimensions Weight Boxed 385mm x 300mm x 300mm HxWxD 4 72kg 5 2 Vi PSU 1A Power Supply 5 2 1 Power Input 100 to 240 Vac 50 60Hz Output 24Vdc 2 5A 5 2 2...

Страница 26: ...acket 5 4 4 Vi B3 Pendant bracket 5 4 5 Vi B6 Pole mount bracket 5 4 6 Vi B7 Dome adaptor 5 4 7 Vi B8 Ceiling Mount Kit 5 4 8 Cables Longer 10metres cable are available where longer runs are required...

Страница 27: ...CMOR Dome Videoswitch Page 23 Vc607a doc Serial Number of dome Notes Notes...

Страница 28: ...CMOR Dome Videoswitch Page 24 Vc607a doc...