CMOR Dome
Videoswitch Page
6
Vc607a.doc
2.2.1 Mains
Input
Connect the incoming fused mains power to the terminal block marked
MAINS INPUT
making sure the LIVE, NEUTRAL and EARTH wires are correctly connected.
Identification MAINS
INPUT
Live
Live (brown) 240Vac 50Hz
Neutral
Neutral (blue) 240Vac 50Hz
Earth Earth
(Yellow/Green)
2.2.2 Connections to dome
Connect the umbilical cable from the dome to the terminal block marked
DOME
.
Identification DOME
CAM2
White Coax signal (dual camera version only)
GND
White Coax screen (dual camera version only)
CAM1 Black
Coax
signal
GND Black
Coax
screen
RS485 (A)
WHITE
RS485 (B)
ORANGE
+24V RED
0V
BLACK and Cable screen
2.2.3 Connections to DVR
Connections to the DVR or other recording/control equipment should be made to the
terminal block marked
DVR/KBD/MONITOR.
Identification DVR/KBD/MONITOR
CAM2*
GND
Camera input (dual camera version only)
CAM1*
GND
Camera input
RS485 (A)
RS485 (A) or (+) dome output
RS485 (B)
RS485 (B) or (-) dome output
Spare Not
connection
GND RS485
ground
1
*Note that the video connection(s) made be made either using the BNC connectors or
the screw terminals, whichever is more convenient.