21
3.3.13 RS485
RS485 addr: (1-255): For F481EP series product, please refer to the camera ID setup
information for the RS485 setup.
RS485 baud rate: 9600bps.
RS485 protocol: Auto-adaptive PELCOD, PELCOP, DH-SD.
Note:
This function is for F481EP, F581EP and F781EP series product only.
3.3.14 SYNC MODE
The system supports INT and LL setup.
Important
The F480CP and F780CP series product do not support the LL synchronization mode.
3.3.15 LANGUAGE
The parameter includes: English, Japanese and etc. The default setup is English.
3.3.16 CAMERA RESET
Please select the reset item and then click the confirm button to restore the factory default setup.
3.3.17 OTHERS
Next: Click it to go to the sub-menu.
Back: click it to return to the previous menu.
Return: click it to exit the menu setup interface.
SAVE ALL: Click it to save current setup.
Important
After you completed the setup, please click the “SAVE ALL” button to save current setup and
then exit the menu. It is to guarantee the camera setup after the power failure.