Infrared detection

The OMV outdoor MotionViewer uses standard infrared detection. The PIR is optimized for the detection of 
individuals. 

Several parameters affect the detection :

•    Subject thermal signature (size, width, temperature and emissivity).

•    Detection environment (ambient temperature, reflectivity of the surfaces, the presence of water or moist 

surfaces).

•    Speed and direction of the movement.

•    OMV setup (tilt, height, lens type, sensitivity).

Important :

It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the 
panel MAINTENANCE menu. 

A red status LED lights up when the OMV is detecting. Use that test to determine the pattern of the detection field.

Multi-purpose 90° 

lens detection pattern 

(standard sensitivity)

Status LED

Blind angle

Detection beams

Individual thermal 

signature at 3 m

Individual thermal 

signature at 12 m

Vehicle thermal 

signature at  12m

Содержание OMV 210

Страница 1: ... and all system devices before mounting system devices Install the detector and other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel Mounting mount detector at the tested location Mounting Use proper tools and hardware Mount came...

Страница 2: ...s continuously or you receive a 9 9 indicating good communication with the control panel 9 Press OK YES to end radio range test then press ESC NO 10 The keypad displays AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired area number appears then press OK YES By default all devices in Area 1 are automatically delayed 11 The display shows NAME LOCATION Enter appropriate device ...

Страница 3: ...impact on the detection distance and on the blind area under the MotionViewer We recommend to slightly tilt the OMV to reduce its detection range and avoid false alarms To precisely determine the tilt angle use a smartphone app like Smart Protector Android or Pitch Gauge iOs Blind Area Max detection distance Tilt Mounting height Max detection distance MULTI PURPOSE 90 LENS Tilt angle 5 10 15 20 30...

Страница 4: ...nViewer has 3 built in wired inputs With these inputs other detection systems can be associated with the OMV IN1 and IN2 inputs Normally open wired inputs These inputs are enabled when the OMV is armed When triggered an INTRUSION event is sent to the panel and the OMV captures a video IN3 input Normally open wired input This input is enabled 24 7 When triggered a TAMPER event is sent to the panel ...

Страница 5: ...ter or moist surfaces Speed and direction of the movement OMV setup tilt height lens type sensitivity Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that test to determine the pattern of the detection field Multi purpose 90 lens detection p...

Страница 6: ...n the screws using a mechanic screwdriver 5 Replace the OMV in its case tighten the screw and install on site 6 Adjust the PIR sensitivity according to the lens in the configuration menu see below 7 It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that...

Страница 7: ...be adapted to the site environment Long range beam lens Pet immune lens horizontal curtain Max detection distance CURTAIN LENS Tilt angle 5 10 15 20 30 Mounting height 2 5 m 16m 11m 8m 6 5m 2 75 m 17m 12m 9m 7m 5m 3 m 18m 13m 9 5m 7 5m 5 5m 3 25 m 14m 10m 8m 5 5m 3 5 m 15m 11m 8 5m 6m 3 75 m 16m 11 5m 9m 6 5m 4 m 17m 12m 10m 7m Curtain lens vertical ...

Страница 8: ... no effect if the installation doesn t comply with the installation recommendations described in this document Adjust sensitivity for the OMV MotionViewer To change the OMV sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OMV OK orYES Enter the detector name then enter the symbol at the end and the chosen digit without space The number...

Страница 9: ... kit to only leave the zones that will be masked as shown below Use the lens replacing procedure shown previously and place the masking kit directly behind the 90 lens Close the lens frame Curtain masking kit A masking kit for curtain lens is provided as well Installing this kit is highly recommended for open air installations As shown below it will reduce false alarms Use the lens replacing proce...

Страница 10: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Страница 11: ...EDs Infrared illumination distance Up to 12m Video Video format MJPEG WMV MJPEG DIFF Frame rate 5 images per second Video duration Programmable 10 seconds by default Video resolution QVGA 320x240 Quality SQ or HQ Average video file size 220 kb Image Format JPEG Resolution VGA 640x480 Quality HQ or SQ Average image file size 8 kb VIDEO PROPERTIES Tamper detection Tilt Position change shock wall and...

Страница 12: ...g of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will help to conserve natural resources For more information about recycling of this product please contact your local municipality your waste disposal service or the company that installed t...

Отзывы: