background image

10

INSTALL SHEET

OMV

 OUTDOOR MOTION VIEWER

Security notes / (FR) Notes de sécurité / (DE) Hinweise zur Sicherheit

Français

•  Retirez les piles avant toute opération de 

maintenance !

•  Attention ! Il y a un risque d'explosion si la batterie 

utilisée est remplacée par un mauvais modèle !

•  Respectez la polarité lors de la mise en place des 

piles !

•  Ne jetez pas les batteries usagées !  

Ramenez-les à votre installateur ou à un point de 
collecte spécialisé.

English

•  Remove the batteries before any  

maintenance !

•  WARNING, there is a risk of explosion if a battery 

is replaced by an improper model !

•  Observe polarity when setting up the batteries!
•  Do not litter the batteries when they are used! 

Dispose of them properly according to Lithium 
Metal requirements

Deutsch

•  Batterien vor jeglichen Wartungsarbeiten 

entfernen!

•  Vorsicht, es besteht Explosionsgefahr, wenn eine 

Batterie durch eine Batterie falschen Models 
ersetzt wird!

•  Achten Sie beim Einsetzen der Batterien auf die 

Polung! 

•  Entsorgen Sie Batterien nicht im normalen 

Haushaltsmüll! Bringen Sie Ihre verbrauchten 
Batterien zu den öffentlichen Sammelstellen.

FCC Regulatory Information for USA and CANADA

FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC 
authorization to operate this equipment.

FCC Part 15.105 Class B 
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 
limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses 
and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does 
cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is 
encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed 
and operated with minimum distance of 20 cm between the radiator and your body.

Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé.
Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada.
Operation is subject to the following two conditions:

This device may not cause harmful interference, and 

This device must accept any interference received, including interference that may cause undesired operation.

Cet appareil est conforme à la Partie 15 des règlementations de la FCC et avec la norme RSS-210 de l’Industrie Canadienne.
Son fonctionnement est soumis aux deux conditions suivantes :

Cet appareil ne doit pas causer d’interférences nuisibles et 

Cet appareil doit accepter toute interférence reçue, y compris les interférences pouvant entraîner un fonctionnement indésirable.

Содержание OMV 210

Страница 1: ... and all system devices before mounting system devices Install the detector and other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel Mounting mount detector at the tested location Mounting Use proper tools and hardware Mount came...

Страница 2: ...s continuously or you receive a 9 9 indicating good communication with the control panel 9 Press OK YES to end radio range test then press ESC NO 10 The keypad displays AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired area number appears then press OK YES By default all devices in Area 1 are automatically delayed 11 The display shows NAME LOCATION Enter appropriate device ...

Страница 3: ...impact on the detection distance and on the blind area under the MotionViewer We recommend to slightly tilt the OMV to reduce its detection range and avoid false alarms To precisely determine the tilt angle use a smartphone app like Smart Protector Android or Pitch Gauge iOs Blind Area Max detection distance Tilt Mounting height Max detection distance MULTI PURPOSE 90 LENS Tilt angle 5 10 15 20 30...

Страница 4: ...nViewer has 3 built in wired inputs With these inputs other detection systems can be associated with the OMV IN1 and IN2 inputs Normally open wired inputs These inputs are enabled when the OMV is armed When triggered an INTRUSION event is sent to the panel and the OMV captures a video IN3 input Normally open wired input This input is enabled 24 7 When triggered a TAMPER event is sent to the panel ...

Страница 5: ...ter or moist surfaces Speed and direction of the movement OMV setup tilt height lens type sensitivity Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that test to determine the pattern of the detection field Multi purpose 90 lens detection p...

Страница 6: ...n the screws using a mechanic screwdriver 5 Replace the OMV in its case tighten the screw and install on site 6 Adjust the PIR sensitivity according to the lens in the configuration menu see below 7 It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that...

Страница 7: ...be adapted to the site environment Long range beam lens Pet immune lens horizontal curtain Max detection distance CURTAIN LENS Tilt angle 5 10 15 20 30 Mounting height 2 5 m 16m 11m 8m 6 5m 2 75 m 17m 12m 9m 7m 5m 3 m 18m 13m 9 5m 7 5m 5 5m 3 25 m 14m 10m 8m 5 5m 3 5 m 15m 11m 8 5m 6m 3 75 m 16m 11 5m 9m 6 5m 4 m 17m 12m 10m 7m Curtain lens vertical ...

Страница 8: ... no effect if the installation doesn t comply with the installation recommendations described in this document Adjust sensitivity for the OMV MotionViewer To change the OMV sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OMV OK orYES Enter the detector name then enter the symbol at the end and the chosen digit without space The number...

Страница 9: ... kit to only leave the zones that will be masked as shown below Use the lens replacing procedure shown previously and place the masking kit directly behind the 90 lens Close the lens frame Curtain masking kit A masking kit for curtain lens is provided as well Installing this kit is highly recommended for open air installations As shown below it will reduce false alarms Use the lens replacing proce...

Страница 10: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Страница 11: ...EDs Infrared illumination distance Up to 12m Video Video format MJPEG WMV MJPEG DIFF Frame rate 5 images per second Video duration Programmable 10 seconds by default Video resolution QVGA 320x240 Quality SQ or HQ Average video file size 220 kb Image Format JPEG Resolution VGA 640x480 Quality HQ or SQ Average image file size 8 kb VIDEO PROPERTIES Tamper detection Tilt Position change shock wall and...

Страница 12: ...g of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will help to conserve natural resources For more information about recycling of this product please contact your local municipality your waste disposal service or the company that installed t...

Отзывы: