Videofied OMV 210 Скачать руководство пользователя страница 2

Programming/RF Testing/Mounting

The following provides summarized steps for device 
programming, testing, and mounting. For complete details, 
refer to the control panel installation manual.

Separate the base from the box

Install 4 3.6V LS14500 SAFT 

batteries observing correct polarity. 

3

 Put control panel into 

Programming/Configuration mode.

Using a programmed 

alphanumeric keypad, proceed 
through menus until the display 
shows ADD A NEW DEVICE.

Press OK/YES. the display shows PRESS PROGRAM 

BUTTON OF DEVICE.

Press and release program button 

on the OMV MotionViewer.

The OMV PIR flashes.

Wait for keypad display to show 

CAMERA(1 - 25) PROGRAMMED. Press 
OK/YES, the display shows RADIO 
RANGE TEST? Press OK/YES again. The 
camera LED starts flashing and keypad 
display shows RF TEST.

Take the OMV camera to its intended mounting location 

and make sure LED flashes continuously or you receive a 9/9 
indicating good communication with the control panel.

Press OK/YES to end radio range test then press ESC/NO.

10 

The keypad displays : 

AREA ALLOCATION : 

AREA : 1

Press either arrow button repeatedly until desired area number 
appears then press OK/YES. By default all devices in Area 1 are 
automatically delayed. 

11 

The display shows NAME + LOCATION: 

Enter appropriate device name/location (up to 16 characters), 
then press OK/YES. The display shows the device number and 
name for your verification. 

12 

Mount the OMV on the MB110 or MBW110 Mounting kit. 

Follow the installation guidelines shown in this document.

13 

Press OK/YES. The display shows FUNCTIONAL DEVICE 

TEST? Press OK/YES and verify camera operation. The 
activation of the LED will determine the detection field.

14 

Press OK/YES to end detection verification.

15 

The display shows OPERATION COMPLETED or ADD A 

NEW DEVICE? Press YES/OK. Repeat steps 1 – 14 for remaining 
cameras.

16 

When finished, exit from configuration mode.

Screw

Program button

2

INSTALL SHEET

OMV

 OUTDOOR MOTION VIEWER

Содержание OMV 210

Страница 1: ... and all system devices before mounting system devices Install the detector and other system devices in the order of the following steps Programming RF Testing program detector and all other devices into the control panel and test RF communication from each intended device location to the control panel Mounting mount detector at the tested location Mounting Use proper tools and hardware Mount came...

Страница 2: ...s continuously or you receive a 9 9 indicating good communication with the control panel 9 Press OK YES to end radio range test then press ESC NO 10 The keypad displays AREA ALLOCATION AREA 1 Press either arrow button repeatedly until desired area number appears then press OK YES By default all devices in Area 1 are automatically delayed 11 The display shows NAME LOCATION Enter appropriate device ...

Страница 3: ...impact on the detection distance and on the blind area under the MotionViewer We recommend to slightly tilt the OMV to reduce its detection range and avoid false alarms To precisely determine the tilt angle use a smartphone app like Smart Protector Android or Pitch Gauge iOs Blind Area Max detection distance Tilt Mounting height Max detection distance MULTI PURPOSE 90 LENS Tilt angle 5 10 15 20 30...

Страница 4: ...nViewer has 3 built in wired inputs With these inputs other detection systems can be associated with the OMV IN1 and IN2 inputs Normally open wired inputs These inputs are enabled when the OMV is armed When triggered an INTRUSION event is sent to the panel and the OMV captures a video IN3 input Normally open wired input This input is enabled 24 7 When triggered a TAMPER event is sent to the panel ...

Страница 5: ...ter or moist surfaces Speed and direction of the movement OMV setup tilt height lens type sensitivity Important It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that test to determine the pattern of the detection field Multi purpose 90 lens detection p...

Страница 6: ...n the screws using a mechanic screwdriver 5 Replace the OMV in its case tighten the screw and install on site 6 Adjust the PIR sensitivity according to the lens in the configuration menu see below 7 It is essential to monitor the proper functioning of the infrared detection using the FUNCTIONAL TEST feature in the panel MAINTENANCE menu A red status LED lights up when the OMV is detecting Use that...

Страница 7: ...be adapted to the site environment Long range beam lens Pet immune lens horizontal curtain Max detection distance CURTAIN LENS Tilt angle 5 10 15 20 30 Mounting height 2 5 m 16m 11m 8m 6 5m 2 75 m 17m 12m 9m 7m 5m 3 m 18m 13m 9 5m 7 5m 5 5m 3 25 m 14m 10m 8m 5 5m 3 5 m 15m 11m 8 5m 6m 3 75 m 16m 11 5m 9m 6 5m 4 m 17m 12m 10m 7m Curtain lens vertical ...

Страница 8: ... no effect if the installation doesn t comply with the installation recommendations described in this document Adjust sensitivity for the OMV MotionViewer To change the OMV sensitivity you need to change the detector name DEVICE CONFIGURATION CHANGE NAME DEVICE OK orYES To select the OMV OK orYES Enter the detector name then enter the symbol at the end and the chosen digit without space The number...

Страница 9: ... kit to only leave the zones that will be masked as shown below Use the lens replacing procedure shown previously and place the masking kit directly behind the 90 lens Close the lens frame Curtain masking kit A masking kit for curtain lens is provided as well Installing this kit is highly recommended for open air installations As shown below it will reduce false alarms Use the lens replacing proce...

Страница 10: ...s However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separati...

Страница 11: ...EDs Infrared illumination distance Up to 12m Video Video format MJPEG WMV MJPEG DIFF Frame rate 5 images per second Video duration Programmable 10 seconds by default Video resolution QVGA 320x240 Quality SQ or HQ Average video file size 220 kb Image Format JPEG Resolution VGA 640x480 Quality HQ or SQ Average image file size 8 kb VIDEO PROPERTIES Tamper detection Tilt Position change shock wall and...

Страница 12: ...g of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health The recycling of materials will help to conserve natural resources For more information about recycling of this product please contact your local municipality your waste disposal service or the company that installed t...

Отзывы: