8.3. Power supply function
The Victron
Phoenix Smart IP43 Charger
range are also suitable for use as a DC power supply, to power equipment without a
battery connected (or while also connected to a battery).
While it’s still possible to use the charger as a power supply without changing any settings, a dedicated ‘Power supply’ mode
exists for this purpose/usage.
If the charger will be used as a power supply, it is recommended to activate ‘Power supply’ mode, as it will disable the internal
charge logic and provide a constant DC supply voltage.
To activate power supply mode:
a. Access the ‘settings’ menu by selecting the 'settings' icon (gear) in the top right corner.
b. Select the 'Function' dropdown arrow to expand the menu, then select ‘Power supply' mode.
c. ‘Power supply' mode will now be enabled; once activated the BULK, ABS, FLOAT and STORAGE LEDs will be illuminated.
d. If required, adjust the desired output voltage and/or the 'Maximum current' limit.
To return the charger back to normal use as a battery charger, access the 'settings' menu and in the ‘Function’ drop down menu
select ‘Charger’ mode again.
Phoenix Smart IP43 Charger
Page 55
Advanced Configuration