CUTMASTER 102
SERVICE
Manual 0-4998
5-6
Problem - Symptom Possible Cause
Recommended Action
FAULT & 80 PSI
indicators flashing.
Gas flow is cycling
ON and OFF.
1. Torch shield cup is loose.
2. Torch tip, electrode or start
cartridge missing.
3. Torch start cartridge is stuck.
4. Open conductor in torch leads.
5. Problem in the torch and leads
switch circuit.
6. Failed components in unit.
1. Tighten shield cup by hand. Do not overtighten.
2. Turn OFF power supply. Remove shield cup. Install missing
parts.
3. Turn OFF power supply. Bleed down system pressure.
Remove shield cup, tip and start cartridge. Check start cartridge
lower end fitting for free movement. Replace if fitting does not
move freely.
4. Replace torch and leads or return to authorized service center
for repair or replacement.
5. Replace torch and leads or return to authorized service center
for repair or replacement.
6. Return to authorized service center for repair or replacement.
Nothing happens
when torch switch
or remote switch
is closed (Or CNC
START signal is
active) No gas flow,
DC LED OFF.
1. Problem in the torch and leads
switch circuit (Remote pendant
switch circuit).
2. CNC Contoller device not
providing Start signal.
3. Failed components in unit.
1. Take Torch and Leads (Remote Pendant) to Authorized Repair
Facility.
2. Contact Controller manufacturer.
3. Return to authorized service center for repair or replacement.
FAULT indicator
flashing and 85 PSI
indicators flashing at
1 cycle per second.
1. Upper O-Ring on torch head is in
wrong position.
2. Torch start cartridge is stuck.
3. Worn or faulty torch parts.
4. Shorted Torch.
1. Remove shield cup from torch; check upper O-Ring position;
correct if necessary.
2. Turn OFF power supply. Bleed down system pressure.
Remove shield cup, tip and start cartridge. Check start cartridge
lower end fitting for free movement. Replace if fitting does not
move freely.
3. Inspect torch consumable parts. Replace if necessary.
4. Replace torch and leads or return to an authorized service
center for repair.
FAULT indicator
flashing and 85 PSI
indicators flashing at
5 cycles per second
1. Low output voltage during pilot.
2. Low output voltage during cut.
3. For Automation Torch only: Tip
contacted work piece during cut
with output correct set above 45
amps.
1) Check torch consumable parts for wear or foreign debris.*
2) Check torch consumable parts for wear or foreign debris.*
3) Cut with Tip OFF the plate.*
*For these modes, to reset the machine, remove the START
signal.
No Fault lights ON, no
arc in torch.
1. Failed components in unit.
1. Return to an authorized service center for repair.
FAULT and 90 PSI
indicators flashing
1. Internal Error
1. Turn the ON / OFF switch OFF then back ON again. If that does
not clear the fault, return to an authorized service center for
repair.
Pilot arc is ON but
cutting arc will not
establish
1. Work cable not connected to
work piece.
2. Work cable/connector broken.
3. Failed components in unit.
1. Connect work cable.
2. Replace work cable.
3. Return to an authorized service center for repair.
Torch cutting is
diminished
1. Incorrect current setting.
2. Worn torch consumables.
3. Poor work cable connection to
work piece.
4. Torch being moved too fast.
5. Excessive oil or water in torch.
6. Failed components in unit.
1. Check and adjust to proper setting.
2. Check torch consumables and replace as needed.
3. Check the connection of the Work Lead to the work piece.
4. Reduce cutting speed.
5. Refer to "Check air quality" in section 3 Torch.
6. Return to an authorized service center for repair.
Содержание CUTMASTER 102
Страница 4: ...This Page Intentionally Blank ...
Страница 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Страница 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Страница 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Страница 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Страница 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Страница 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...
Страница 111: ...This Page Intentionally Blank ...