CUTMASTER 102
Manual 0-4998
SERVICE
5-29
LOGIC PCB 3 SIGNALS
J1
Signal info is the same as MAIN PCB 1 - J2 connector.
J3-1
+5VDC
J3-2
Pressure Transducer output 0.5 to 5 VDC / 0 - 100 psi
J3-3 Common
LOGIC PCB 3 LED INDICATORS
NORMAL INDICATION
FIRMWARE VERSION
ERROR MESSAGE
D1 +12VDC
D2 MAX PRESSURE X.7
Over Pressure
D3 90 PSI
X.6
Internal Error
D4 85 PSI
X.5
Shorted torch (Output Fault)
D5 80 PSI
X.4
Tip Missing
D6 75 PSI
X.3
Start Signal active during power up
D7 70 PSI
X.2
Parts-In-Place Fault (PIP)
D8 65 PSI
X.1
Input Power Fault
D9 MIN PRESSURE
X.0
Low Pressure
D10
AC
1.X
D11 OVERTEMP
2.X
D12
GAS
3.X
D13
DC
4.X
D14 ERROR
5.X
LOGIC PCB 3 TEST POINTS
TP1
Common
TP2 +12VDC
TP3 +5VDC
TP4 +3.3DCV
TP5
0.5 to 5 VDC / 0 - 100 psi
TP6 +1.8VDC
TP7
Potentiometer Current Demand (0-3.3VDC)
Содержание CUTMASTER 102
Страница 4: ...This Page Intentionally Blank ...
Страница 20: ...CUTMASTER 102 INTRODUCTION Manual 0 4998 2T 4 This Page Intentionally Blank ...
Страница 26: ...CUTMASTER 102 INSTALLATION Manual 0 4998 3T 2 This Page Intentionally Blank ...
Страница 30: ...CUTMASTER 102 OPERATION Manual 0 4998 4 4 This Page Intentionally Blank ...
Страница 46: ...CUTMASTER 102 OPERATION Manual 0 4998 4T 16 This Page Intentionally Blank ...
Страница 80: ...CUTMASTER 102 SERVICE Manual 0 4998 5 34 This Page Intentionally Blank ...
Страница 91: ...CUTMASTER 102 Manual 0 4998 PARTS LIST 6 9 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13 ...
Страница 105: ...CUTMASTER 102 Manual 0 4998 APPENDIX A 5 This Page Intentionally Blank ...
Страница 111: ...This Page Intentionally Blank ...