Output Power Derating -continued
All module configurations: The FlatPAC-EN/EN MI or an individual output may be limited by module power limitations.
1. One cannot exceed the output power rating of the FlatPAC-EN regardless of the module capability.
2. Also see Output Power vs. Input Voltage charts on page 21.
3. Please note that FlatPAC-EN configurations that uses Molex outputs connectors are limited to 9A/pin (27A per output).
This is a Molex connector limitation, NOT a module power limitation. Westcor’s online configuration tool (VSPOC) will
not provide a FlatPAC-EN/EN MI solution for requirements that exceed the 27A limitation.
Rev. 3/2009