FlatPAC-EN™ and FlatPAC-EN MI
EN Compliant Autoranging Switcher
Overview
The FlatPAC-EN/EN MI is an ultra low profile switching power supply that provides up to 500 Watts from up to 4
isolated outputs. It operates on either 115 or 230 Vac nominal (47-63 Hz), or 250-380 Vdc. It can be populated
with either VI-200/VI-J00 or Maxi/Mini/Micro Vicor converters. The use of these converters gives the FlatPAC-
EN/EN MI the inherent power flexibility typical of all Vicor products. With dimensions of 1.4" H (35,6mm) x 5.0"
W (127mm) x 9.2" L (233,7mm), the FlatPAC-EN/EN MI provides a power density greater than 7W/in
3.
It is facto-
ry configured to meet user output requirements. Note: The FlatPAC-EN/EN MI does not have an internal fan.
The MI version is a rugged chassis designed specifically for COTS and harsh environment applications
Using the PowerBench configurator tool available on vicorpower.com, anybody can now configure a FlatPAC-EN
(and other Westcor power supplies) online.
Standard Features
• Power Factor Correction (passive): Power Factor (Typical) 0.70 (>75% Load)
• Input Voltage: 90-132/180-264 Vac
1
, 47-63 Hz, or 250-380 Vdc
• Maximum Power Output: 500W (105/190Vac min.)
425W for EN61000-3-2 compliance
• Up to 4 isolated user specifiable outputs
• Conducted EMI:
FCC Class A
EN 55022 Class A
FCC Class B
EN 55022 Class B
Mil-STD 461 may require external filter
• Harmonic Attenuation to EN61000-3-2/A14
2
•
Compliant to EN61000-4-4 (Electrical Fast Transient/Burst) and EN61000-4-5 (Surge Immunity)
•
MI version meets Mil-STD 810 for Shock and Vibration with extended temp range
• MI version also available with -40C temp rating
•
Efficiency (typical) > 70%
•
Autosense
3
•
RS-232 microcontroller interface
• Output overcurrent protection on all outputs
• Size: 1.4" H (35,6mm) x 5.0" W (127,0mm) x 9.2" L (233,7mm)
•
Safety Agency Approvals: cURus, cTUVus, CE Mark
1
Derates to 260W@90Vac, 400W @ 180 Vac.
2
For output power
≤
425W, not to exceed an input current of 3.33 A rms at 230 Vac, 50 Hz.
3
This feature is implemented in all converter slots (except with Micro modules). Autosense allows automatic local sensing
when remote sense connections are not made. The FlatPAC-EN/EN MI will operate in remote sense mode when remote
sense connections are made. Refer to page 16 for more information on Autosense.
Optional Features
•
Current Share Board for unit to unit power sharing - See page 26 and page 27
•
Connector kits (# 19-130044)
• Conformal coating available on select MI models - contact factory
•
-40oC Operation, Mil-STD 810 Shock and Vibration (MI rugged chassis only)
Part Numbering
FlatPAC-EN/EN MI
FLx1
-
x2 x3 -xxxx (-x4)(-x5) x1
Number of outputs
e.g.
FL4-13-6544
x2
Number of VI-200/VI-J00 modules
x3
Number of Maxi/Mini/Micro modules
xxxx
Sequential number assigned by Westcor
(-
x4
)
Optional Factory assigned: G - RoHS
(-x5)
Optional versions
Note:
x5
= MI for rugged chassis, = MC for rugged chassis with conformal coating
Rev. 2/2012
Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474
Pg. 3