Specifications
(Typical at 25°C, nominal line and 75% load, unless otherwise specified)
G
ENERAL
Number of Outputs
1-4
Modules
VI-200/VI-J00, VE-200/VE-J00: Maxi/Mini/Micro
Efficiency
Typically > 70%
Safety Agency Approvals
cURus – UL 60950-1, CSA 60950-1
cTUVus – EN 60950-1, UL 60950-1, CSA 60950-1
CE Mark – Low Voltage Directive, 73/23/EEC amended by 93/68/EEC
Vibration
Mil-STD 810 Minimum Integrity (MI chassis only)
Shock
Mil-STD 810 40G Functional Shock (MI chassis only)
Maximum Output Power
Up to 500 Watts; 425 Watts for EN 61000-3-2/A14 compliance
(not to exceed input current of 9A)
(105/190 Vac minimum input)
I
NPUT
Input
90-132/180-264 Vac 47-63Hz
250-380 Vdc
Inrush Current
14 A pk @ 115 Vac and 230 Vac
Line/Load Regulation
VI200/VI-J00:± 0.2% max.10% to full load; ± 0.5% max. No load to 10% load
Line Regulation*
Maxi/Mini/Micro:± 0.20% max. to 0.3% max LL to HL, Full Load
Ride Through Time
500W
400W
@ 115Vac (typical)
12ms
15ms
@ 230Vac (typical)
16ms
18ms
Harmonic Distortion
EN61000-3-2 A/14 (For output power
≤
425W or input current not
in excess of 3.33 A rms at 230 Vac, 50 Hz.)
Conducted EMI
FCC and EN 55022 Class A
(certain configurations meet EN 55022 Class B)
Mil-STD 461 may require external filter - contact factory
Power Factor
>.70
Transient Burst Immunity
EN61000-4-4
Surge Immunity
EN61000-4-5
Voltage Dips
EN61000-4-11
Dielectric Withstand
Primary to Chassis GND = 1,500 V
RMS
Primary to Secondary = 3,000 V
RMS
Secondary to Chassis GND = 500 V
RMS
* See Vicor module specifications. A preload may be necessary for modules trimmed down below 90% of normal output voltage.
O
UTPUT
VI-200/VI-J00 Modules
Parameter
MIN.
TYP.
MAX.
UNITS
NOTES
Setpoint Accuracy*
0.5
1
%
of Vnom
Load/line Regulation
±0.2
%
10% to Full Load
Load/line Regulation
±0.5
%
Load to 10%
Temperature Regulation
0.01
0.02
%/°C
Over rated temp.
Long Term Drift
0.02
%/K hours
Output Ripple & Noise:
VI/E-200
100
mV p-p
See module design guide
VI/E-J00
100
mV p-p
for exact specifications
Voltage Trim Range
VI-200/VI-J00 Slots
50-110
% V out
±
10% on 10-15 Vout
Total Remote Sense Compensation
0.5
Volts
Autosense. See pg.14
OVP Set Point
1
115
125
135
%Vout
Recycle Power
Current Limit
105
115
125
% of I max
Auto Recovery
Short Circuit Current
20 (105
2
)
130
%
Overtemperature Limiting
Not available on VI-J00
* For special and adjustable voltages, maximum setpoint accuracy is 2% of Vnom.
1 131% Nominal for Booster Modules. No OVP for VI-J00
2 VI-J00 modules only.
Pg 18
Vicor 800-735-6200 Westcor Division 408-522-5280 Applications Engineering 800-927-9474
Rev. 2/2012
FlatPAC-EN/EN MI Design Guide