66
Circuit. Grounded Circuit: “0;” Open Circuit: “1.”
Alarm out Contact: Set the transfer mode of the alarm signal, Local contact or
Net contact.
Local Contact: I/O out is triggered by I/O alarm in, motion detection alarm, video
contents analysis, TF card out, network link down or heart beat lost. Default:
Local Contact.
When the value of I/O out 1 is “1,” the switch status will be on.
When the value of I/O out 1 is “0,” the switch status will be off.
Net Contact: I/O out is controlled by the surveillance management software.
Note:
This function can work with some Digital Video Surveillance
Management software. If Net contact is selected, users must set the IP of the
Alarm server as the server IP of the system. After the necessary settings in
software, users can control the relay switches remotely via the software. For
detailed information, refer to the Digital Video Surveillance Management
Software Operation manual.
Alarm Server IP: Set the IP address of alarm server. When an alarm occurs, the
alarm server is notified.
Alarm out Contact
Users can set the responding action for each switch signal I/O alarm in, motion
detection alarm, video contents analysis, TF card out, network link down or IP
address conflict from the options: Alarm out 1 (if Net Contact is selected, this
option is unavailable), TF card, Mail, FTP or Audio. When setting is completed,
click “Save” button.
Note: When “FTP” or “Mail” is selected, FTP or SMTP parameters must be set
in Network Settings; refer to Section 4.3.2 or Section 4.3.3 for details.