XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control
Technical Information
••••
19
Technical Information
ELECTRICAL
Input Voltage:
V1400X-IDL:
120 V, 60 Hz.
V1400X-IDL-230:
230 V, 50 Hz.
Power Consumption:
9 Watts.
Heat
Equivalent:
0.5 btu/min (0.13 cal/min).
Note: These figures represent the conversion of 100% of the electrical energy to heat. Actual percentage of
the heat generated will be less and will vary from product to product. These figures are provided as an
aid in determining the extent of cooling required for an installation.
Line Cord:
Standard 3-conductor SV No. 18 AWG cable with grounding
plug available in 120 and 230 VAC.
Fuse:
120 VAC: 5mm x 20mm, 0.25 A, slo-blo.
230
VAC:
5mm
x
20mm,
0.125
A,
slo-blo.
European Community
(CE)
Standards:
EN 50081-1 generic emissions.
EN-50082-1
generic
immunity.
CONTROLS & CONNECTORS
(refer to Figure 18 for panel locations)
Power
(LED):
Red front panel LED illuminates when unit is powered-up.
Power (connector):
Rear panel 120 or 230 VAC grounded female connector.
CPU (LED):
Yellow front panel LED indicates CPU condition, intelligent
mode only.
CPU (J11 connector):
6-pin removable Screw Terminal Block connector.
Station (LEDs):
Green front panel LEDs indicate Station conditions. Stations
are ready for communication after initial power-on booting
has occurred (approximately 45 sec).
Station (STAT J1 - J10):
6-pin removable Screw Terminal Block for each connector.
DL/IDL Switch:
Slide switch on rear panel used to toggle the intelligent mode
on and off (DL = non-intelligent mode/ IDL intelligent mode).
Unit must be reset (temporarily unplugged) for the mode
change to take effect.