background image

16  

••••

 Maintenance 

XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control 

Maintenance 

This unit does not require any scheduled maintenance. If a unit does not operate and replacement of the fuse, 
as described below, does not correct the problem, contact Vicon’s Service Department. 
 

Fuse Replacement 

If the unit is plugged into a known good outlet, and does not display an illuminated Power LED, replace the 
Fuse. The Fuse is located in the Power Block at the rear of the unit, as shown in Figure 17. 

 

1.  Unplug the Line Cord from the outlet and the Power Block. 

 

 

2.  Remove the Power Block Fuse Cover and remove the Fuse from the Active Slot. 

 

 

3.  Replace the Fuse with one specified for the appropriate model, as stated in the Technical Information 

Section of this manual. 

 

 

4.  Replace the Fuse Cover, connect the Line Cord and confirm that the Power LED illuminates. 

 

 

Figure 17 

Rear Panel Power Block 

Содержание V1400X-IDL

Страница 1: ...s system has not been designed to be used in life critical situations and must not be used for this purpose Copyright 2002 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUPPAUGE NEW YORK 11788 TEL 631 952 CCTV 2288 FAX 631 951 CCTV 2288 TOLL F...

Страница 2: ......

Страница 3: ......

Страница 4: ......

Страница 5: ... INSTALLATION 6 Unpacking and Inspection 6 Physical Installation 6 Accessory Kit 6 Desk Mount 6 Rack Mount 6 Cabling 6 Power Connection 6 CPU Connection 7 V1300X DVC V1300X RVC Keypads 7 V1400X DVC System Console 9 Receivers and Domes 10 Terminal Block Applications 10 RJ 45 Connector Applications Surveyor2000 11 OPERATION 13 Requirements and Characteristics 13 Addressing 13 Basics 13 Operation Ver...

Страница 6: ...lacement 16 SHIPPING INSTRUCTIONS 17 REFERENCE 18 Cable Recommendations 18 RS 422 Protocol 18 Manual References for Associated Equipment 18 CPUs 18 Input Devices 18 Output Devices 18 TECHNICAL INFORMATION 19 ELECTRICAL 19 CONTROLS CONNECTORS 19 OPERATIONAL 20 MECHANICAL 20 ENVIRONMENTAL 20 ...

Страница 7: ...XX017 01 00 Rev 702 V1400X IDL Intelligent Distribution Line Control Quick Installation 3 Quick Installation Q U I C K I N S T A L L A T I O N Q U I C K I N S T A L L A T I O N ...

Страница 8: ...telligent control via microprocessor controlled circuitry that can individually detect the status of each Station and isolate it from the remaining stations Thus the IDL can prevent stations that are locked incorrectly wired or that have high noise levels from interfering with other stations NOTE RS 422 is an industry standard data transmission protocol used for external device communication in th...

Страница 9: ...rmatted to present distinct methods of installation for experienced and novice installers For Experienced Installers Start at the Quick Installation sub section of the Installation section to begin Refer to the subsequent sections of Installation Operation and Maintenance for detailed descriptions of any method For Novice Installers Proceed to the Installation section and choose the appropriate sc...

Страница 10: ...ubber bumpers a replacement Fuse a power cord with the correct molded plug and 11 pre terminated 6 position Terminal Block plug in Modules Desk Mount The IDL can be used on a solid desk surface Use the 4 rubber bumpers provided to make a stable base Attach an adhesive backed bumper to each corner of the bottom surface and press firmly Rack Mount The IDL can be rack mounted using hardware supplied ...

Страница 11: ...r on the CPU 3 Terminate the IDL wire ends of the cable into the CPU J11 Terminal Block and press it into the Panel Connector The IDL uses standard RS 422 protocol on connectors J1 J10 6 pin Terminal Block connectors Prepare a length of Shielded Dual Twisted Pair Cable to have 6 dressed wires Use the pin designations in Figure 4 for J1 J10 Refer to the applicable I O Device manual for pin designat...

Страница 12: ... Press the 6 position Terminal Block end of the cable into the STAT 1 J1 connector 4 Optional Connect Slave Keypads as described in Vicon Installation and Operation Manual X777 5 Connect additional cables to consecutive Station connectors 2 3 4 etc NOTE All unused station STAT port Terminal Blocks are terminated with an end of line jumper Remove this small wire between the Response In signal Pin 5...

Страница 13: ...onnect the System Console RJ 45 connector end of the 6 foot cable to the RJ 45 connector on the System Console as shown in Figure 6 3 Connect the other end of the 6 foot cable RJ 45 connector to the Termination Box 4 Connect additional cables to consecutive Station connectors 2 3 4 etc NOTE All unused station STAT port Terminal Blocks are terminated with an end of line jumper Remove this small wir...

Страница 14: ...e to the appropriate Screw Terminal Block on the Receiver as shown in Figures 7 13 3 Press the 6 position Terminal Block end of the cable into the STAT 1 J1 connector 4 Optional Connect a daisy chained Receiver as described in the corresponding Vicon Receiver Installation and Operation Manual 5 Connect additional cables to consecutive Station connectors 2 3 4 etc NOTE All unused station STAT port ...

Страница 15: ...ibed above Connect the 6 dressed wires to the RJ 45 Termination Box 2 Connect the Receiver RJ 45 connector end of the 6 foot cable to the appropriate connector as shown in Figure 13 3 Connect the other end of the 6 foot cable RJ 45 connector to the Termination Box 4 Optional Connect a daisy chained Receiver as described in the corresponding Vicon Receiver Installation and Operation Manual 5 Connec...

Страница 16: ...ligent Distribution Line Control NOTE The RJ 45 connector can be used instead of the Terminal Block on the Surveyor2000 Figure 12 STAT 1 J1 STAT 10 J10 Pin Definition for V15UVS Cable Figure 13 STAT 1 J1 STAT 10 J10 Pin Definition for Surveyor2000 Cable ...

Страница 17: ...types can be used with an IDL unit Operation of the IDL is transparent to the user when proper monitor partitioning and camera seize control is established on the CPU The DL IDL switch must be selected for intelligent mode prior to powering on the unit If the switch is toggled with power applied the unit must be reset temporarily unplug unit for the mode to be toggled Refer to the Instruction Manu...

Страница 18: ...connected to the IDL Figure 16 shows 3 IDLs daisy chained to a CPU IDLs have 9 remaining STAT ports for I O Devices except for the last unit which has 10 STAT ports available IDL 1 communicates directly with the CPU passing information from and to its connected I O devices IDL 2 communicates with the CPU through IDL 1 which passes information from and to its connected I O devices However if IDL 1 ...

Страница 19: ... is powered on and functional 1 Setup all Output Devices in accordance with their corresponding Instruction Manuals listed in the Reference Section of this manual The most important factors to setup are the addresses and baud rate The addresses must be unique for each output and the baud rate must be the same for all outputs 2 Toggle the DL IDL switch on the rear panel to the IDL position Power on...

Страница 20: ...ood outlet and does not display an illuminated Power LED replace the Fuse The Fuse is located in the Power Block at the rear of the unit as shown in Figure 17 1 Unplug the Line Cord from the outlet and the Power Block 2 Remove the Power Block Fuse Cover and remove the Fuse from the Active Slot 3 Replace the Fuse with one specified for the appropriate model as stated in the Technical Information Se...

Страница 21: ... from countries in Europe contact Vicon Industries U K Ltd Brunel Way Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the p...

Страница 22: ...ble 1 Manual References for Associated Equipment CPUs V1200X V1200X Series Transmitter CPU X379 V1300X Microprocessor Based Control System X553 VPS328 V1422 VPS328 V1422 Digital Control Installation Operation X826 Input Devices V1300X DVC RVC Intelligent Remote Control Panels X777 V1400X DVC System Console XX090 Output Devices V1200R LM Multiple Receiver X512 V1301R Outdoor Receiver X506 V1311RB U...

Страница 23: ...m 0 125 A slo blo European Community CE Standards EN 50081 1 generic emissions EN 50082 1 generic immunity CONTROLS CONNECTORS refer to Figure 18 for panel locations Power LED Red front panel LED illuminates when unit is powered up Power connector Rear panel 120 or 230 VAC grounded female connector CPU LED Yellow front panel LED indicates CPU condition intelligent mode only CPU J11 connector 6 pin...

Страница 24: ...s and indication will be displayed accordingly with the front panel LED Control Format RS 422 protocol data full duplex operation at 4800 9600 or 19200 baud MECHANICAL Mounting Desk mount bumpers provided or Rack mount Dimensions Height 1 7 in 43 mm Width 19 0 in 483 mm Depth 7 5 in 191 mm Weight 6 5 lb 2 9 kg Construction Steel chassis and cover Finish Black baked enamel chassis and cover ENVIRON...

Страница 25: ...ope Headquarters Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Brussels Office Planet II Unit E Leuvensesteenweg 542 B 1930 Zaventem Belgium 32 2 712 8780 Fax 32 2 712 8781 Far East Office Unit 5 17 F Metropole Square 8 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...

Отзывы: