10
••••
Installation
XX017-01-00 Rev 702 V1400X-IDL Intelligent Distribution Line Control
Receivers and Domes
For Terminal Block applications, connect the 6 dressed
wires from the other end of the Station 1 (J1) cable to
the Terminal Block on the appropriate device. Use the
pin designations in Figures 7-13 for connection.
Terminal Block Applications
1. Fabricate the RS-422 protocol cable as described
above. It is recommended to label both cable ends.
2. Connect the end (open wires) of the cable to the
appropriate Screw Terminal Block on the Receiver,
as shown in Figures 7-13.
3. Press the 6-position Terminal Block end of the
cable into the STAT 1/J1 connector.
4. (Optional) Connect a daisy-chained Receiver as
described in the corresponding Vicon Receiver
Installation and Operation Manual.
5. Connect additional cables to consecutive Station
connectors (2, 3, 4, etc.).
NOTE: All unused station (STAT) port Terminal Blocks
are terminated with an end-of-line jumper. Remove this
small wire between the Response In - signal (Pin 5)
and Ground (Pin 4) when using the port.
Figure 7
STAT 1 (J1) - STAT 10 (J10) Pin Definition for
V1200RLM-1 Cable
Figure 8
STAT 1 (J1) - STAT 10 (J10) Pin Definition for
V1319R Cable