5
To call up an auto tour
1.
Enter one of the following code combinations to call up the
designated auto tour:
Press "8+6+PRESET" to call up Auto Tour 1;
Press "8+7+PRESET" to call up Auto Tour 2;
Press "8+8+PRESET" to call up Auto Tour 3;
Press "8+9+PRESET" to call up Auto Tour 4.
3.5 Setting and Calling up Autopan
With the AUTOPAN features, the domes can automatically move
back and forth between two pre-defined positions (AUTOPAN
boundaries). This allows the domes to continuously scan through
an area when no manual operation is performed.
The parameters of autopan, such as direction, speed, dwell time,
title, can be set via AUTOPAN SET menu. The start/end point and
calling of autopan are programmed via Vicon system keypad.
To program and call up an autopan, follow the steps below.
To define the start point Autopan
1.
Use the joystick to move the camera to the position that is
desired as the start point.
2.
Press PROG button and hold, press the number key 2, and then
release PROG, to enter into the Preset Store mode.
PROG
2
PROG
Press & hold
Press the number key
Release
3.
Press PRESET button, press number keys 9 and 8, and then
press PRESET button to start programming autopan.
PRESET
9
Press
Press the number key
1
PRESET
Press the number key
Press
4.
The following overlay messages will be displayed. Press AUX2
to set the left autopan limit.
To define the end point Autopan
1.
Move the joystick to the position to be set as the end point.
2.
Press AUX3 to set the right autopan limit.
3.
Set the keypad to Normal operating mode.
Note:
Vicon control protocol only allows one autopan to be
programmed.
How to call up AUTOPAN
1.
Set the keypad to Normal operating mode.
PROG
1
PROG
Press & hold
Press the number key
Release
2.
Press the Autopan key (A/P) to start or stop the autopan.
Moving the joystick will also cancel the autopan operation.
3.6 Special Operations
Other presets to control the dome are provided. The following
table outlines the operations of special functions with Vicon
keypad.
Preset
Number
Store/Recall
Dome Preset Functions
Using Vicon Control System
1 to 79
Store/Recall
Preset Position
80 to 85
Store/Recall
Normal Tours
86 to 89
Store/Recall
Auto Tours
90
Store
Pan/Tilt Locked
94
Store
Enter Dome OSD Menu
95
Store
Redetect Control Protocol
96
Store
Program Partition Sectors
97
Store
Soft Reset
98
Store
Set Auto Pan Limits
99
Store
Set Manual Pan Limits
8
PROG
1
PROG
Press & hold
Press the number key
Release