To call up an auto tour 

1.

 

Enter one of the following code combinations to call up  the 
designated auto tour: 
Press "8+6+PRESET" to call up Auto Tour 1; 
Press "8+7+PRESET" to call up Auto Tour 2; 
Press "8+8+PRESET" to call up Auto Tour 3; 
Press "8+9+PRESET" to call up Auto Tour 4. 

 

3.5 Setting and Calling up Autopan 

With the AUTOPAN features, the domes can automatically move 
back and forth between two pre-defined positions (AUTOPAN 
boundaries). This allows the domes to continuously scan through 
an area when no manual operation is performed. 
 
The parameters of autopan,  such as direction, speed, dwell time, 
title, can be set via AUTOPAN SET menu. The start/end point and 
calling of autopan are programmed via Vicon system keypad. 
 
To program and call up an autopan, follow the steps below.   

 
To define the start point Autopan 

1.

 

Use the joystick  to move the camera to the position that is 
desired as the start point. 

 

2.

 

Press PROG button and hold, press the number key 2, and then 
release PROG, to enter into the Preset Store mode. 

PROG

2

PROG

Press & hold

Press the number key

Release

 

3.

 

Press PRESET button, press number keys  9 and 8, and then 
press PRESET button to start programming autopan. 

PRESET

9

Press 

Press the number key

1

PRESET

Press the number key

Press 

 

4.

 

The following overlay messages will be displayed. Press AUX2 
to set the left autopan limit. 

 

 

To define the end point Autopan 

1.

 

Move the joystick to the position to be set as the end point. 

 

2.

 

Press AUX3 to set the right autopan limit. 

3.

 

Set the keypad to Normal operating mode. 

 

 

 

 
 
 
 
 

Note: 

Vicon control protocol only allows one autopan to be 

programmed. 
 

How to call up AUTOPAN 

1.

 

Set the keypad to Normal operating mode.

 

PROG

1

PROG

Press & hold

Press the number key

Release

 

2.

 

Press the Autopan key (A/P) to start or stop the autopan. 
Moving the joystick will also cancel the autopan operation. 

 

3.6 Special Operations 

Other presets to control the dome are provided. The following 
table outlines the operations of  special functions with Vicon 
keypad. 

 

Preset 
Number 

Store/Recall 

Dome Preset Functions   
Using Vicon Control System 

1 to 79 

Store/Recall 

Preset Position 

80 to 85 

Store/Recall 

Normal Tours 

86 to 89 

Store/Recall 

Auto Tours 

90 

Store 

Pan/Tilt Locked 

94 

Store 

Enter Dome OSD Menu 

95 

Store 

Redetect Control Protocol 

96 

Store 

Program Partition Sectors 

97 

Store 

Soft Reset 

98 

Store 

Set Auto Pan Limits 

99 

Store 

Set Manual Pan Limits 

 

PROG

1

PROG

Press & hold

Press the number key

Release

 

Содержание Surveyor MKII

Страница 1: ...in the documentation This system has not been designed to be used in life critical situations and must not be used for this purpose Document Number 8009 8283 30 01 Product specifications subject to ch...

Страница 2: ...l other trademarks that may appear belong to their respective proprietors FCC Warning The Surveyor MKII Analog PTZ Domes comply with the FCC rules Operation is subject to the following two conditions...

Страница 3: ...nded by manufacturer Position power source and related wires to assure they will be kept away from ground and access way Refer all service matters to qualified personnel Save product packaging to ensu...

Страница 4: ...e The Surveyor MKII analog domes provide video transmission over coaxial cable They are compatible with the leading controllers in the market and can be controlled directly by Vicon keypads controller...

Страница 5: ...surveillance area automatically A description title for the autopan can be programmed and stored in the domes The domes after receiving no command for a programmed period of time will automatically re...

Страница 6: ...rations Instructions Camera Call up NOTE The dome cameras must be called up put under the control of via the keypad before operation or programming To call up a camera enter the camera ID number and p...

Страница 7: ...Tour is a series of defined steps the dome can take and can be called up by a keypad The dome can save horizontal vertical and zoom operations and it can repeat these operations accurately when appli...

Страница 8: ...r keys 9 and 8 and then press PRESET button to start programming autopan PRESET 9 Press Press the number key 1 PRESET Press the number key Press 4 The following overlay messages will be displayed Pres...

Страница 9: ...ore than 5 minutes it will exit automatically 4 2 MAIN MENU 1 SYS INFO SET 1 1 SYSTEM SET Display the current S N number Display the camera ID number Display the broad ID Display the control protocol...

Страница 10: ...to tour number Set auto tour title Clear title Clear auto tour 3 4 HOME RETURN SET Set home return position Home return time Power off save 3 5 NORM TOUR SET Tour number Action and Time The dome can b...

Страница 11: ...COMM MODE LENS TYPE VERSION V1 00 05 BAUD RATE 485 RETURN 255 EXIT P236B CURRENT S N Function Display the current serial number of the domes MODEL Function Display the model name CAM ADDR Function Dis...

Страница 12: ...OFF HUMIDITY Function Turn the Humidity title ON OFF PRESSURE Function Turn the Pressure display ON OFF Only available on pressurized model dome PRESSURE ALARM Function Enable Disable the Pressure Lo...

Страница 13: ...WHITE BALANCE SET EXPOSURE SET SPECIAL FUNCTION EXIT RETURN 4 4 1 ZOOM SET DIGITAL ZOOM Function Enable disable digital zoom Options OFF Disable digital zoom function default ON Enable digital zoom fu...

Страница 14: ...tor when changing the R gain value The greater the number is the more reddish the picture becomes WB B Function Allow manual adjustment of B gain value for customer white balance Options 000 255 The c...

Страница 15: ...black and white show a striking contrast When the target is exposure is correct indoor or outdoor the image can be presented clearly The WDR function can be only be enabled when the Prior Mode of Exp...

Страница 16: ...the title is complete TITLE CLEAR Function Clear some or all of the preset titles Options 001 255 Clear the selected preset title ALL Clear all of the preset titles Note When the set value surpasses 2...

Страница 17: ...the cursor to the first character of title 2 Move the operation hand to select character or blank 3 Move the cursor to the next character 4 Repeat steps 2 and 3 to complete the title TITLE CLEAR Func...

Страница 18: ...ote PRESET 80 85 PRESET keypad switch is set at OPERATE position can call up tour 1 6 The ACT will be determined by the TIME in the TOUR If the tour is set with time only no act the dome will perform...

Страница 19: ...K NO Function Selected the area to be masked Options 001 016 options MASK STATUS Function Enable disable the privacy mask function of the area Options OFF Display the area default ON Mask the area Not...

Страница 20: ...occurs once the alarm has been acknowledged Options NONE Indicates a no action command that disables the automatic preset call default PRESET 001 PRESET 032 Select one of the 32 presets for automatic...

Страница 21: ...entry of the title item 2 Deflect the joystick downward or upward to select a suitable character or a space 3 Move the cursor to the next entry 4 Repeat steps 2 and 3 until the entire title has been e...

Страница 22: ...splay the lens direction and angle in real time When the COMPASS DISP is set to ON the COMPASS SET menu is shown as below SET THE NORTH Operation Set COMPASS DISP to ON deflect cursor to SET THE NORTH...

Страница 23: ...ART and END H POSI and the START and END V POSI values by moving the joystick left or right Be sure to avoid crossing over the values THRESHOLD Function Sets the amount of activity required to generat...

Страница 24: ...above Follow the instructions shown on the screen during operation For Preset Autopan Auto Tour setup and calling up shortcut operations for special functions refer to the table that follows This show...

Страница 25: ...es Zoom Selected Area Yes PELCO D Protocols VICON PELCO P D auto detect Number of Address 1 254 Baud Rate 2400 4800 9600 19200bps Manual Speed Pan 400 s Tilt 150 s Preset Speed 400 s maximum Pan Trave...

Страница 26: ...nsitivity Color mode IR Cut On 1 4 lux NTSC 1 60s PAL 1 50s 0 1 lux NTSC 1 4s PAL 1 3s B W Mode IR Cut Off 0 01 lux NTSC 1 4s PAL 1 3s Horizontal 550TVL S N Ratio 50dB Video Output 1 0 0 2Vp p Backlig...

Страница 27: ...rolled after successful initiation New camera ID has not been activated Recycle the power Protocol or Baud rate Dip switch settings are incorrectly chosen Proper set the Protocol and Baud rate Wrong c...

Страница 28: ...nal by the original end user The sole remedy under this Warranty is that defective equipment be repaired or at the Company s option replaced at Company repair centers provided the equipment has been a...

Страница 29: ...Vicon product whether resulting from breach of warranty or any other legal theory Notwithstanding the foregoing Vicon total liability for all claims under this warranty shall not exceed the price pai...

Страница 30: ...VICON INDUSTRIES INC For office locations visit the website www vicon security com...

Отзывы: