20
PHASE ADJUST
Function: Manually adjust the line phase.
Option: 1-198
4.6.6 MOTION CONTROL
The dome capable of Motion Detection and can be enabled and
configured in the following steps.
First configure a preset position that will be used for Motion
Detection. Refer to 3.3, Setting and Calling Up a Preset.
PRESET NO
Function:
Set the preset number to be used for Motion Detection.
Option:
1 - 79
DETECT SET
Function:
Moving the joystick to the RIGHT or pressing A/P will
allow you to configure the motion detection for the preset number
set in the first step above. The menu below will then be displayed.
STATUS
Function:
Changing the STATUS to ON will display a Red square
on the screen. This is your Motion Detection Zone or ‘Frame’.
The size and position can be adjusted by configuring the START
and END H POSI and the START and END V POSI values by
moving the joystick left or right. Be sure to avoid crossing over
the values.
THRESHOLD
Function:
Sets the amount of activity required to generate an
Alarm.
Option:
0 – 255.
The lower the value the more sensitive the
detection.
INTERVAL
Function:
Sets the amount of time that motion must occur before
an alarm is activated.
Option
: 0 – 255. The higher the number the longer it will take for
motion to trigger an alarm.
The 2 settings above may need some testing and refinement in
order to give the desired response.
ALARM OUT
Function:
Triggers an event when motion is detected.
Option:
Presets 1-32, AutoTour 1-4, AutoPan 1-4, AuxON/OFF
FRAME NO
Function:
Each preset can have up to 4 Frames (Motion Detection
Zones) configured with different Alarm responses.
Option:
1-4
4.6.7 RELAY DRIVER
The menus below configure the on-board Relay (AUX 1).
POWER ON STATE
Function:
Sets the state of the relay when the dome is powered on.
Option:
ON/OFF
OUTPUT TYPE