Mounting
There are two types of mounting recommended for the server, either desktop or rack.
Desktop
The desk or table must provide a surface of suitable strength for the Kollector Network Server’s weight of
26 lb (11.8 kg). In addition, there must be area left around the cabinet to provide suitable airflow for cooling.
Do not place heavy items on the cover.
Rack
The server was designed to be mounted in a standard 19-inch (483mm) wide vertical rack. Use the provided
rack mount ears to connect the recorder to the rack using hardware provided with the rack.
It is recommended that at least ¼ standard rack height of space be left in between multiple servers mounted
in the same rack for cooling purposes.
WARNING
: Failure to leave space for cooling between servers may result in malfunctioning and possible
failure.
Installing the Kollector Network Server
After the server is mounted permanently, follow the steps in this section to install associated unit hardware.
•
Step 1: Connecting the Hardware
, below
•
Step 2: Connecting External Hardware to Termination Boxes
, page 9
•
Step 3: Connecting the Power Supply
, page 10
IMPORTANT NOTES:
The connection of external hardware may require simple hand tools. Do not apply power or plug-in the server
to any outlet until instructed to do so.
Disable the AC power to prevent installer injury and damage to the unit.
Before beginning the hardware installation, ensure that the following environmental conditions have been met:
•
The surface on which the
ViconNet
hardware is to be placed must be level.
•
The room or area designated for the
ViconNet
hardware installation must be well ventilated.
XX155-01-00 Rev 1105 Kollector Network Server
Installation
•
7