background image

The Air Cleaning DynaFilter

®

How Your Humidifier Works

The Vicks® Cool Mist Humidifier produces a cool mist through cyclone technology. The motor-driven impeller draws up 
water through a pickup tube. Centrifugal force throws the water through a screen into the vortex chamber, breaking up 
the water into a superfine, cool mist. This humidifier adds water vapor to the surrounding air, enabling the user to breathe 
better and sleep more comfortably.

This humidifier should not be left unattended in a closed room since air could become over-saturated and leave 
condensation in front of the unit, on walls and furniture. It is recommended to leave room door partially open.

The Vicks Cool Mist Humidifier includes the exclusive Protec Air Cleaning DynaFilter PK14-3W.

Under normal environmental conditions, the filter cartridge should 
be replaced every two months. Replacement time will vary depending upon the concentration 
of pollutants in the air. If you notice heavy dirt accumulation on the filter or if the humidifier 
output is significantly reduced, 

it’s time to change to a new DynaFilter!

 Protec DynaFilter 

PK14-3W cartridges are available at leading pharmacies and drug departments. You may also 
order directly from Kaz (see Order Information in this manual).

1.

 

 CAUTION: UNRAVEL CORD BEFORE USE.

 Failure to do so could cause overheating and possible fire hazard. Always 

disconnect cord at wall plug before removing the Top Housing or when humidifier is not in use.

2.

  

PLACE HUMIDIFIER IN A SAFE POSITION

 on floor, table or other FIRM, FLAT and LEVEL surface. Protect rug, floor or 

furniture by placing unit on a waterproof non-conducting pad or mat for protection against inadvertent spillage. 

Do not 

place any object over the humidifier; it could block air openings.

 

 Cord should be out of the way, where it cannot be pulled or stepped on.

 

 When used therapeutically, the humidifier should be placed at least 4 feet from bedside and out of the reach 
of children.

3.

 

 

FILL CAREFULLY.

 The exclusive FillChannel™ permits convenient filling without removing the Top Housing.

 

Pour cool tap water into FillChannel™. Fill until water level reaches Water Level Indicator on the front of bowl.

 

IMPORTANT:

 

DO NOT OVERFILL, as this will cause water spillage and possible damage to floors or furniture.

4.

 

PLUG IN HUMIDIFIER.

 Plug power cord into wall.

 

 CAUTION: DO NOT PLUG IN THE CORD WITH WET HANDS; ELECTRIC SHOCK COULD RESULT.

This product has a polarized plug (one blade is wider than the other) as a safety feature. The plug will fit into a 
polarized outlet only one way. If the plug does not fit properly into the outlet, reverse the plug. If it still does not fit, 
contact a qualified electrician. 

Do not attempt to defeat this safety feature.

 

CAUTION:

 Turn off the humidifier if moisture condenses on surfaces or walls. Room air may be excessively humid.

 

IMPORTANT:

 To maintain proper operation of your humidifier, be sure to follow 

Care and Cleaning

 instructions.

Care and Cleaning 

(continued)

4.

 

 Carefully loosen the Pickup Tube from the housing by holding the Disk and rotating the 
Pickup Tube counterclockwise in the direction of the “OFF” arrow located at the base of 
the Pickup Tube. 

(Figure A)

5.

 

Soak Pickup Tube in undiluted white vinegar. Let stand for 20 minutes.

6.

 

 

Dampen a soft, clean cloth or sponge with undiluted white vinegar and wipe  
out Base, Pickup Tube and walls around the Pickup Tube.  

CAUTION: DO NOT

 use soap, detergents or abrasive cleaners.

7.

 

 Rinse Pickup Tube and Base thoroughly in clean, warm water until scale particles  
are removed.

8.

 

 

Wipe exterior surfaces of the Top Housing with a soft, dry cloth. DO NOT IMMERSE OR 
SPRAY WATER ON THE TOP HOUSING. You are now ready to disinfect the base.

Disinfecting the Base

1.

  Fill Base with 1 teaspoon of household bleach in 1 gallon of water. 

Place the Pickup Tube in the Base and let remain for 20 minutes. 
Stir every few minutes to ensure that all surfaces are coated.

2.

 

 Empty Base after 20 minutes. Thoroughly rinse the Base and Pickup Tube with water 
until bleach smell is gone. Dry with clean cloth or paper towel.

3.

 

Wipe all exterior surfaces of the Top Housing with a soft, dry cloth.  

   BE CAREFUL NOT TO IMMERSE OR SPRAY WATER ON THE TOP HOUSING. ELECTRIC 

SHOCK MAY RESULT OR HUMIDIFIER MAY BE DAMAGED.

4.

 

 Carefully re-attach Pickup Tube by inserting the prongs into the slots in  
the Disk. While holding the Disk steady, rotate the Pickup Tube clockwise in  
the direction of the “ON” arrow located at the base of the Pickup Tube. 

(Figure B)

5.

 

Replace Top Housing on Base. Humidifier is now ready for use.

End Of Season Maintenance 

OR WHEN HUMIDIFIER WILL NOT BE IN USE FOR AT LEAST ONE WEEK

1.

  

Clean and dry the humidifier thoroughly as per the 

Weekly Maintenance 

instructions above.

2.

     

Store in a cool, dry location. 

DO NOT

 STORE WITH WATER INSIDE THE BASE.

E

F

ON

OFF

Figure A

E

F

ON

OFF

Figure B

Read and Save These Instructions

OUTPUT NOZZLE

BASE

TOP HOUSING

WATER 
FILLCHANNEL™

WATER LEVEL
INDICATOR

AIR INLET GRILL

Care and cleaning

Tap water may contain pollutants and minerals (scale) that can deposit on the inner surfaces of the humidifier. Such scale 
can accelerate the growth of microorganisms and it is important that periodic cleaning is performed as outlined below. More 
frequent cleaning may be necessary if you notice a heavy buildup of scale.

Daily Maintenance

1.

 

Unplug cord from electrical outlet.

2.

  

Remove Top Housing and place upside down on a flat surface. Do not set down on the Pickup Tube. Rinse Base, wipe 
clean, and dry with a clean cloth or paper towel.

3.

  

Wipe exterior surfaces of the Top Housing with a soft, dry cloth. CAUTION: DO NOT USE WATER TO CLEAN THE TOP 
HOUSING. ELECTRIC SHOCK MAY RESULT OR HUMIDIFIER MAY BE DAMAGED. DO NOT IMMERSE TOP HOUSING IN WATER.

4.

 

Replace Top Housing. Humidifier is now ready for use.

Weekly Maintenance

Removing Scale

1.

 

Unplug cord from electrical outlet.

2.

 

Remove Top Housing and place 

upside down

 

on a flat surface. 

Do not set down on the Pickup Tube.

3.

 

Empty any remaining water from Base.

Отзывы: