background image

1

MISTRAL EVOLUTION HYBRID

USER MANUAL

www.vicidbs.com

Version 1.03.0000

TECH SUPPORT

Europe, Asia, Africa, Australia & New Zealand:

[email protected]

USA, Canada, Central & South America:

[email protected]

Italy

[email protected] 

VICI AG INTERNATIONAL

Parkstrasse 2

CH-6214 Schenkon

Switzerland
tel:  +41 41 925-6200

fax:  +41 41 925-6201

web: www.vicidbs.com

APPLICABLE MODELS

This manual is applicable to the following models:
•  Mistral Evolution Hybrid

Version 1.03.0000

Содержание MISTRAL EVOLUTION HYBRID

Страница 1: ...ort vicidbs com USA Canada Central South America techsupportusa vicidbs com Italy service vicidbs com VICI AG INTERNATIONAL Parkstrasse 2 CH 6214 Schenkon Switzerland tel 41 41 925 6200 fax 41 41 925...

Страница 2: ...iew 6 5 3 Connections 7 5 4 Power Supply Settings 7 5 5 Transport and Storage 7 6 SCHEMES 8 6 1 Fluidics 8 6 2 Electrical 9 7 STARTING THE GENERATOR 10 8 SOFTWARE 11 8 1 Overview of the Menus 11 8 2 P...

Страница 3: ...N HISTORY VERSION DATE COMMENT CHANGE 1 00 0100 01 10 2017 Layout and initial release VICI DBS 1 01 0000 12 20 2018 Update 1 02 0000 05 18 2020 New layout images and graphics VICI Gig Harbor Group 1 0...

Страница 4: ...veral unique advantages over all other nitrogen generators commercially available 2 1 Symbol Definitions SYMBOL DESCRIPTION General warning Caution is necessary when operating the device or control cl...

Страница 5: ...y time If the Mistral Evolution is used in a way not specified by VICI DBS the protection provided by the equipment could be compromised 3 2 Instrument Safety Instructions The Mistral Evolution Hybrid...

Страница 6: ...barg psig 7 100 Technology Carbon molecular sieve Warm up time minutes 20 Electrical supply 110 120V 60Hz 220 240V 50Hz Power consumption watts 1800 Noise level 55 dBA 1 meter Dimensions mm in 482W x...

Страница 7: ...w Command Buttons x3 LED Indicator Lights Backlit Display 5 2 Back View Relay Alarm Outlet Compressor Box Cooling System Dust Silencer Filter Outlet Water Purge Outlet N2 with Valve Outlet Pressure Se...

Страница 8: ...talled to transform internally the requested voltage to 110 115 V 50 60Hz The list of voltage and frequencies settings possible are bellow In any case the voltage of the power supplied must stay at 10...

Страница 9: ...back to the factory for recalibration or repair the Mistral Evolution Hybrid should be packed in its original packing with the inlets and outlets protected against any accidental penetration of dust o...

Страница 10: ...S DOCUMENT AND THE INFORMATION WHICH IT CONTAINS SHALL NOT BE USED EXPLOITED OR SOLD AND SHALL NOT BE REVEALED OR DISCLOSED TO OTHERS WITHOUT THE EXPRESS WRITTEN PERMISSION OF VICI THIS DOCUMENT SHALL...

Страница 11: ...Mistral Evolution to an external water tank 4 Turn the generator on switch in back 5 Press the MENU button and scroll until you get the PARAMETER menu Press the SELECT button 6 Go into each sub menu...

Страница 12: ...perature C F C Flow Unit Sets desired unit of measure for flow rate L min ft3 min L min Auto Start Choose to automatically start production upon powering on or not Yes No No Display Contrast Sets desi...

Страница 13: ...situation it does not make sense to have the Mistral Evolution run continuously and throw away the produced Nitrogen The Mistral Evolution is able to handle an external tank management The Mistral Ev...

Страница 14: ...ight size of the tank will be around 225 L 9 2 Where to Get the Tank As the size of the tank will be large for application and in addition legislation is different from one country to another DBS does...

Страница 15: ...0 h service kit 10 ALARMS PRE ALARMS 10 1 Pre Alarms Precursors of the alarms Do not stop the device ITEM DESCRIPTION Temperature The temperature inside the cabinet is over the maximum limit Check if...

Страница 16: ...ure is too high and do not cool the compressors The compressors are overheating Check and eventually replace the compressors Int tank pressure min The pressure in the internal reservoir is too low The...

Страница 17: ...intenance Every 8 000 10 000h the compressors must be replaced DB EVO 002 OF 302 Air compressor hybrid and gas station 13 SPARE PARTS VICI DBS P N DESCRIPTION DB EVO 001 Complete Heat Exchanger DB EVO...

Страница 18: ...66 Adapter for AF20 to FID S FID T Rack N2 Tower DB FIL010 Maintenance kit 4000h for MISTRAL EVO includes 1 white sil 3 blue sil 1 cart DB 10617 Outlet N2 on off Valve G1 4 for Mistral DB 10620 Silenc...

Отзывы: