2.2.1.3 Piezoelectric accelerometer (ICP) input modules
Module
Input Range
Input Sensitivity
Maximum Processed Range (BW)
Acceleration
Velocity
Displacement
ICPM-1.13-500
1.13 g Peak
500 mV/g
1.13 g Peak
(0.7 to 1000 Hz)
28 mm/s Peak
(0.7 to 1000 Hz)
2000 µm Peak-to-Peak
(0.7 to 1000 Hz)
ICPM-5.65-500
5.65 g Peak
500 mV/g
5.65 g Peak
(0.7 to 1000 Hz)
56 mm/s Peak
(0.7 to 1000 Hz)
2000 µm Peak-to-Peak
(0.7 to 1000 Hz)
ICPM-1.13-100
1.13 g Peak
100 mV/g
1.13 g Peak
(0.7 to 1000 Hz)
28 mm/s Peak
(0.7 to 1000 Hz)
2000 µm Peak-to-Peak
(0.7 to 1000 Hz)
ICPM-5.65-100
5.65 g Peak
100 mV/g
5.65 g Peak
(0.7 to 1000 Hz)
28 mm/s Peak
(0.7 to 1000 Hz)
2000 µm Peak-to-Peak
(0.7 to 1000 Hz)