[9]
98MANALIDP10AV Rev. A 8/16/11
Sensor Fill Fluid
Silicone Oil (DC 200), or Fluorinert (FC-43).
Minimum Allowable Absolute Pressure vs. Process Temperature
With Silicone Fill Fluid
With Fluorinert Fill Fluid
At full vacuum: Up to 121°C (250°F)
Refer to Figure 2.
Power-Up Time
Less than 2.0 seconds for output to reach approximately 3.5 mA, and then at the
electronic damping rate to the final measured variable value.
Electrical Connections
Field wires enter through PG 13.5 or 1/2 NPT threaded entrances on either side of the
electronics housing. Leads terminate under screw terminals and washers on the
terminal block in the field terminal compartment. To maintain RFI/EMI,
environmental, and explosion proof ratings, unused conduit connection must be
plugged with metal plug (provided), inserted to five full turns.
Process Connections
IDP10 transmitters are connected to the process via a 1/4 NPT thread or any one of a
number of optional process connectors.
Supply Current
Power supply must be capable of providing 22 mA current for the IDP10-A and 3 mA
current for the IDP10-V. Ripple of up to 2 V pp (50/60/100/120 Hz) is tolerable, but
instantaneous voltage must remain within specified range.