4
3.
Technical data of boiler
Tab. no.1
Dimensions, operating temperatures a electrical values of boiler
Number of sections
pc
3
4
5
6
7
Boiler design
B
11BS
Appliance category
I
2H
Heat output G 36 BM - natural gas
kW
12-17
18-26
27-34
35-41
42-49
Weight
kg
100
123
147
175
199
Water space volume
l
9,2
11,4
13,6
15,8
18
Diameter of smoke socket
mm
110
130
160
170
180
Boiler dimensions - width
mm
485
485
570
740
740
- depth x height
mm
733 x 935
773 x 935
Water working overpressure
kPa
(bar)
400 (4)
Water test overpressure
kPa
(bar)
800 (8)
Heating water maximum temperature
°C
85
Return water minimum temperature
°C
45
Noise level
dB
max. 65 dB (A)
Chimney draught
mbar
min. 0,025
Boiler connections - heating water
Js
1 1/2“
- return water
Js
1 1/2“
- gas
Js
½"
Tab. no. 2 Thermal - technical parameters of boiler equipped with SINGLE STAGE GAS VALVE and
designated for NATURAL GAS combustion
(thermal power 34,16 MJ.m
-3
, gas temperature 15 °C and bar. air pressure 1013,25 mbar)
Number of sections
pc
3
4
5
6
7
Rated heat output maximum
kW
17
26
34
41
49
Rated heat output minimum
kW
12
18
27
35
42
Rated heat input maximum
kW
18,5
28,5
37
45
53,7
Rated heat input minimum
kW
13,3
19,9
29,9
38,8
46,5
Gas volume flow rate at maximum heat output
m
3
.h
-1
1,980
2,953
3,920
4,727
5,605
Gas volume flow rate at minimum heat output
m
3
.h
–1
1,390
2,072
3,141
4,041
4,837
Efficiency at maximum heat output
%
90,5 – 92
Efficiency at minimum heat output
%
90,5 – 90
No
x
category
2
Combustion products temperature in smoke flue at
maximum heat output
°C
90 – 120
Combustion products temperature in smoke flue at
minimum heat output
°C
80 – 90
Real volume of dry combustion products at maximum
heat output
m
3
.m
-3
23,33
19,23
23,89
20,66
18,25
Real volume of dry combustion products at minimum
heat output
m
3
.m
-3
25,09
27,52
28,67
23,65
25,09
Connecting gas overpressure
mbar
20
Gas overpressure on burner nozzles at maximum heat
output
mbar
13,2
15,8
14,2
14,7
14,6
Gas overpressure on burner nozzles at minimum heat
output
mbar
6,8
7,8
8,9
10,8
10,6
Number of cool. sticks on a tube
pcs
3
3
3
3
3
Number of nozzles
pcs
2
3
4
5
6
Nozzles diameter
mm
2,52
2,52
2,52
2,45
2,45
Connecting gas overpressure
mbar
13
Gas overpressure on burner nozzles at maximum heat
output
mbar
10
11
11
11,7
11,5
Gas overpressure on burner nozzles at minimum heat
output
mbar
4,7
4,8
6,8
8,8
8,6
Number of cool. sticks on a tube
pcs
3
3
3
3
3
Number of nozzles
pcs
2
3
4
5
6
Nozzles diameter
mm
2,7
2,7
2,7
2,7
2,7
The boiler is set at nominal values of the power output at the production company according to Table No. 2
(one-stage gas valve - natural gas)
Содержание GRAND G 36
Страница 1: ...Hercules U26 N vod k obsluze VIADRUS GRAND G 36 MANUAL FOR BOILER OPERATION AND INSTALATION...
Страница 34: ...34...
Страница 36: ...36 Date of revision 16 2013 GB...
Страница 37: ...Hercules U26 N vod k obsluze VIADRUS GRAND G 36 MANUAL FOR BOILER OPERATION AND INSTALATION...
Страница 54: ...18...
Страница 58: ...22...
Страница 60: ...24 Date of revision 32 2013 GB...