25
4. Check all joints of gas supply piping sys
-
tem. Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak. Correct all leaks at once.
5. Reconnect fireplace and equipment
shutoff valve to gas supply. Check recon-
nected fittings for leaks.
Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)
1. Close equipment shutoff valve (see
Figure 40).
2. Pressurize supply piping system by either
opening propane/LP supply tank valve
for propane/LP gas fireplace or opening
main gas valve located on or near gas
meter for natural gas fireplace or using
compressed air.
3. Check all joints from propane/LP supply
tank or gas meter to equipment shutoff
valve (see Figure 41, for propane/LP or
Figure 42, for natural gas). Apply noncor
-
rosive leak detection fluid to all joints.
Bubbles forming show a leak. Correct
all leaks at once.
Figure 40 - Equipment Shutoff Valve
Open
Closed
Equipment
Shutoff Valve
Figure 41 - Checking Gas Joints for
Propane/LP Gas Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment Shutoff Valve
Figure 42 - Checking Gas Joints for
Natural Gas Fireplace
Gas
Meter
Gas Valve
Equipment
Shutoff Valve
FIREPLACE
INSTALLATION
Continued
pRESSURE TESTING FIREpLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see
Figure 40).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural
gas fireplace.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 41 for
propane/LP or Figure 42 for natural gas).
Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak.
Correct all leaks at once.
5. Light fireplace (see
Operation
, page 28).
Check all other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 28).
REMOvING/REpLACING GLASS
DOOR
CAUTION: Do not operate
this fireplace with a broken glass
door panel or without the glass
door panel securely in place. For
replacement part information see
Replacement Parts
, page 38.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not re-
move if glass is hot. Keep children
and pets away from glass.