VENTING INSTALLATION
Continued
Number Description
CVVK-58 Ceiling Vertical Vent Kit
(Includes: 30° Offset Return, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
3' Pipe, 4' Pipe, Firestop Plate,
Firestop Thimble, Storm Collar,
Roof Flashing [0/12 - 6/12], 38
Screws)
CHVK-58 Corner Horizontal Vent Kit,
(Includes 90° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
6" Pipe, 18 Screws)
HHTK-58 High Wind Round Horizontal
Termination Kit (Includes Round
Termination, Wall Firestop, 45°
Elbow)
HHT-58 High Wind Round Horizontal
Termination Kit, Galvanized
HTS-58 Horizontal Square Termination,
Galvanized. HTKS-58 Horizontal
Square Termination Kit (Includes:
Square Termination, Wall
Firestop, 45° Elbow)
VT-58
Vertical Round Termination,
Galvanized
SC-58
Storm Collar, Galvanized
WF-58
Wall Firestop, Galvanized
RF-58-6 Roof Flashing - 0 to 6/12 Pitch,
Galvanized
RF-58-12 Roof Flashing - 6/12 to 12/12
Pitch, Galvanized
VR-58
Vertical Restrictor, Galvanized
S-58
Vinyl Siding Standoff, Galvanized
WS-58
Wall Strap
CS-58
Cathedral Ceiling Support
FP-58
Firestop Plate
SF-58
Stucco Flashing -
For use with HTS-58
RF-58
Flat Roof Flashing
OSR58-30 30° Offset Return
FIREPLACE
INSTALLATION
ELECTRICAL SUppLY CONNECTION
CAUTION: Disconnect the
electrical power to the supply
circuit before attempting to con-
nect or service this appliance.
WARNING: This appliance,
when installed must be electri-
cally grounded in accordance
with local code or in the absence
of local code, with the current
National Electric Code, ANSI/
NFPA 70
.
A prewired junction box receptacle with
strain relief is provided on the right side of
the cabinet for hard wiring unit to a 15 Amp,
120 VAC, 60 Hz grounded branch circuit. If
installation demands that electrical supply be
connected from left side, entire receptacle
box can be relocated to left side by following
these instructions:
Note:
If you do not need to relocate the junc-
tion box to connect electric supply, follow
steps 8 through 11 only
1. Remove 2 screws and outer cover with
strain relief bushing on right side of cabi-
net (see Figure 26).
2. Remove inner retaining screw on junction
box mounting tab.
3. Slide junction box up until screw mounting
tab is lined up to notch in outer cabinet.
4. Swing junction box out and slip retaining
flange out through slot in outer cabinet.
Figure 26 - Relocating Junction Box
Receptacle and Electrical Supply
Connection
J-Box Cover
with Strain
Relief
J-Box
Cover
Romex
Cable
J-Box with
Receptacle
J-Box Cover with
Strain Relief
Screw/Tab
Retainer