Figure 33 - Connecting Wall Switch to 

Control Valve

To Wall Switch 

Accessory

INSTALLING OpTIONAL WALL 
MOUNT SWITCH - GWMS2

1.  Connect  one  terminal  of  25  ft.  wire  for 

wall  switch  to  TPTH  terminal  on  valve. 
Connect  remaining  wire  terminal  to  TH 
terminal on valve. Make sure that wire ter

-

minals are in positions on unit as pictured 

in Figure 33. If wires are not connected as 
shown switch will not work.

2.  Route  25  ft.  wire  through  openings  pro

-

vided on the sides of burner system to a 

convenient location to mount your switch.

3.  Connect  one  bare  wire  end  to  each  of 

terminal of GWMS2 wall switch.

4.  Install wall switch and cover in the wall.

IMPORTANT

: Do not use any other wire than 

that provided with the GWMS2 wall switch kit. 

Do not exceed 15 ft. of distance from the valve 

connection. Using wire of higher gauge or turns 
or exceeding the minimum distance will increase 

resistance at the control valve causing unreli-

able performance of fireplace controls.

Figure 34 - Attaching Alkaline Battery to 

Receiver

9-Volt 
Alkaline 
Battery 

Receiver 

Terminal 
Wires 

Battery Clip 

Figure 35 - Mounting Remote Receiver to 

Bracket

Installing 9-Volt Alkaline Battery in Hand-
Held Remote Control Unit 

1.  Remove battery cover on back of remote 

control unit.

2.  Attach terminal wires to a 9-volt alkaline 

battery (not included). Place battery into 

battery housing.

3.   Replace battery cover onto remote control 

unit. 

Figure 36 - Installing Battery in Hand-

Held Remote Control Unit

9-Volt 
Battery

Battery 
Housing

Battery Cover

Terminal 
Wires

Remote Control Unit

Towards Front

REMOTE ON OFF

Remote Receiver

Plastic Mounting Clips

INSTALLING OpTIONAL WIRELESS 
HAND-HELD REMOTE CONTROL 
FOR MILLIVOLT IGNITION - HRC100 
AND HRC200 SERIES

NOTICE: Use only alkaline bat-

teries (not included).

Installing Remote Receiver

1.  Open  bottom  louver  and  locate  switch 

bracket on the right.

2.  Locate  battery  clip  mounted  on  back  of 

the receiver. Slide a 9-volt alkaline battery 

(not included) through clip.

3.  Attach  terminal  wires  to  battery  (see 

Figure 34).

4.  Connect  wires  from  receiver  to  TH  and 

TPTH to control valve (see Figure 33).

5.  Locate  the  two  plastic  mounting  clips 

provided with kit.

6.  Use  the  clips  to  mount  receiver  on 

remote  mounting  bracket  as  shown  in 

Figure 35.

Содержание CD36T-M

Страница 1: ...ors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Im...

Страница 2: ...and Safety Stan dard Title 24 CFR Part 3280 in the United States This fireplace is only for use with the type s of gas indicated on the rating plate A conversion kit is supplied with the fireplace Thi...

Страница 3: ...re trying to assemble op erate or service this fireplace Improper use of this fireplace cancauseseriousinjuryordeath from burns fire explosion electrical shock and carbon monoxide poisoning DANGER Car...

Страница 4: ...nually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint and dust from carpeting...

Страница 5: ...alanced and sealed gas operating unit It is highly efficient because it uses outside air for combustion while independently heating the indoor air Figure 2 Common Fireplace Locations Flush with a wall...

Страница 6: ...osts Discard bottom tray once unit is moved into position Clearances Minimum clearances to combustibles for the fireplace are as follows Back and sides 0 Perpendicular walls 12 Floor 0 Ceiling to louv...

Страница 7: ...O NAILING FLANGES 56 3 4 12 1 4 TO OPENING 28 5 8 These dimensions allow for 1 of clearance at the sides and back of fireplace 0 clearance is also permitted at all sides if framed Figure 6 Unit Dimens...

Страница 8: ...Figure 7 Clearances for Combustible Mantels MANTEL CLEARANCES Figure 7 shows projected mantel depths at various heights above the top of the louver opening Figure 8 shows the minimum al lowable distan...

Страница 9: ...ove paved side walk or a paved driveway located on public property 84 213 3 cm minimum M clearance under veranda porch deck 12 30 5 cm minimum N clearance above a roof shall extend a minimum of 24 61...

Страница 10: ...attic spaces Install horizontal venting with a 1 4 rise for every 12 of run toward the termination WARNING Read all instruc tionscompletelyandthoroughly before attempting installation Failure to do so...

Страница 11: ...nds of pipes have locking lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe sections together and twist one section clockwise approximately...

Страница 12: ...nt as sembly attached toward wall and insert vent pipe into horizontal termination Pipe overlap should be a minimum of 1 1 4 Slide wall firestop against interior wall sur face and attach with screws p...

Страница 13: ...1 30 Max 69 1 4 Min 2 74 Max 81 1 2 Min 3 98 Max 94 Min 4 122 Max 106 Min 5 146 Max 159 Min 9 20 Max T O H Wall Firestop Straight Adjustable Pipe 24 Max Horizontal Square Termination 90 Elbow Corner I...

Страница 14: ...g Using Two 90 Elbows Venting with Two 90 Elbows Vertical V Horizontal H Horizontal H2 7 Min 10 Max 8 Min 12 Max 9 Min 14 Max 10 Min 16 Max 11 Min 18 Max 13 Min 20 Max 90 Elbow 90 Elbow T O H Figure 1...

Страница 15: ...x 10 3 4 inside dimensions as shown in Figure 11 on page 11 using framing lumber the same size as the ceiling joists If area above ceiling is an insulated ceiling or an attic space you must use firest...

Страница 16: ...or vent pipe 2 Cut and frame ceiling joist to dimensions shown in Figure 11 page 11 3 Determine where firestop plate should be attached to thimble by test fitting thimble into framing Thimble should b...

Страница 17: ...ertical Round High Wind Termination Figure 25 Vertical Venting Configuration with No Horizontal Run Vertical Round High Wind Termination Vertical Venting V 40 Max Note Install a VR 58 vertical restric...

Страница 18: ...shing OSR58 30 30 Offset Return Fireplace Installation ELECTRICAL SUPPLY CONNECTION CAUTION Disconnect the electrical power to the supply circuitbeforeattemptingtocon nect or service this appliance WA...

Страница 19: ...sure that the electrical power to the outlet is turned off before proceeding with blower instal lation Failure to do this may result in serious injury Fireplace Installation Continued Model BK Install...

Страница 20: ...mately 12 in front of blower see Figure 29 Figure 29 Location of Wiring Diagram Decal Model May Vary From Illustration Wiring Diagram Decal 6 in Front of Blower Fireplace Installation Continued Model...

Страница 21: ...e leads and make sure wire routing is not pinched or in a precarious position Cor rect accordingly 8 Turn on power to duplex outlet if previ ously turned off per warning in column 1 page 19 9 Plug in...

Страница 22: ...e Battery to Receiver 9 Volt Alkaline Battery Receiver Terminal Wires Battery Clip Figure 35 Mounting Remote Receiver to Bracket Installing 9 Volt Alkaline Battery in Hand Held Remote Control Unit 1 R...

Страница 23: ...or propane LP connection only the installer must supply an external regulator The external regulator will reduce incoming gas pressure You must reduce incoming gas pressure to between 11 and 14 of wat...

Страница 24: ...louver door panel by gently pulling forward 2 Route flexible gas line provided by in staller from equipment shutoff valve to fireplace Route flexible gas supply line Figure 39 Connecting Flexible Gas...

Страница 25: ...Propane LP Supply Tank Gas Valve Equipment Shutoff Valve Figure 42 Checking Gas Joints for Natural Gas Fireplace Gas Meter Gas Valve Equipment Shutoff Valve Fireplace Installation Continued Pressure T...

Страница 26: ...n running turn off and let coolbeforeaccessingorservic ing the unit Figure 44 Removing Top Louver Trim Panel Panel Tabs Top Louver Trim Panel Door Pin Hanger Bracket WARNING Handle glass door panelwit...

Страница 27: ...w steps under Removing Replacing Glass Door page 25 to access the logs and burner Assemble logs and add burner treatments as follows 1 Position base log onto burner log mounts see Figure 46 Note Cut o...

Страница 28: ...o clear out any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you don t smell gas go to the next step 6 The pilot is located by the...

Страница 29: ...on Figure 49 Setting the Selector Switch Gas Control Knob and Variable Control Knob for Remote Operation On Off Series Model HRC100 Hold the control button on the hand held remote until burner turns o...

Страница 30: ...to lock unlock the keypad on the hand held remote in the MANU or AUTO mode to prevent inadvertent op eration i e children operating the hand held remote control etc The keypad is locked in either on o...

Страница 31: ...If burner flame pattern differs from that de scribed turn fireplace off see To Turn Off Gas to Appliance page 28 see Troubleshooting page 35 Conversion Instructions The conversion kit must be installe...

Страница 32: ...ed with kit The number 30 is stamped on the sleeve for identification Insert small end of new pilot orifice into barrel and thread until tight with allen wrench 4 Line up notch on pilot hood to positi...

Страница 33: ...mately 25 in lbs see Figure 59 3 Install identification label enclosed with gas valve regulator to valve body where it can easily be seen see Figure 59 Conversion Instructions Continued O F F P I L O...

Страница 34: ...s page 38 for detail on ordering No substitutions may be made See Removing Replacing Glass Door page 25 for instruc tions for replacing glass door WARNING Do not operate fireplace with the glass door...

Страница 35: ...ion 3 Gas control knob not pressed in while in PILOT position 4 Air in gas lines when in stalled 5 Depleted gas supply pro pane LP models only 6 Pilot is clogged 7 Gas regulator setting is not correct...

Страница 36: ...lace damaged burner 3 Replace gas control 1 Problem will stop after a few hours of operation 1 Turn gas control knob to LO position and let warm up for a minute 2 Operate burner until air is removed f...

Страница 37: ...nd correct all vent connections see Installation Planning page 11 5 Tighten or replace glass door see Removing Replacing Glass Door page 25 6 Replace faulty components 7 Check for proper installation...

Страница 38: ...warranty Parts Under Warranty Contact authorized dealers of this product If they can t supply original replacement part s call DESA Heating LLC at 1 866 672 6040 When calling DESA Heating LLC have rea...

Страница 39: ...rs Only LTC36B Rolled Louver Trim Kit Brushed Brass LTC36P Rolled Louver Trim Kit Platinum WALL MOUNTED THERMOSTAT CONTROL KIT GWMT1 Allows easy wall access for thermostatic operation of your fireplac...

Страница 40: ...www desatech com 118531 01C 40 Parts Fireplace Assembly for Model CD36T M 1 2 8 10 9 1 1 12 3 16 5 6 7 13 19 1 4 1 3 2 4 14 15 17 18 11...

Страница 41: ...4 114880 01 Heat Deflector 1 5 114875 02 Fireplace Surround 1 6 114876 02 Fireplace Top 1 7 116016 02 Fireplace Top Insulation 1 8 114873 01 Louver Bottom Assembly 1 9 114872 01 Louver Top Assembly 1...

Страница 42: ...www desatech com 118531 01C 42 parts BURNER ASSEMBLY FOR MODEL CD36T M 1 2 3 5 20 9 18 11 10 19 12 6 7 17 13 14 16 15 4 8...

Страница 43: ...P Gas 1 5 27206 Burner Orifice 44 Natural Gas 1 26482 Burner Orifice 55 Propane LP Gas 1 6 26808 Valve Bracket 1 7 24389 Tube 3 8 Dia x 11 Aluminum 1 8 24360 Pilot Bracket 1 9 14500 Fitting 3 8 MPT x...

Страница 44: ...proved by DESA Heating LLC Warranty parts must be obtained through authorized dealers of this prod uct and or DESA Heating LLC who will provide original factory replacement parts Failure to use origin...

Отзывы: